Gamma Luxe Cannon 600 Z IP Скачать руководство пользователя страница 17

 

 

17 

Cleaning and maintenance

 

 

Now ignoring maintenance and cleaning is very good way of creating problems "down the road" 
and many companies and installations do just that. However the net result is, no matter what the 
fixture, premature failure! 
Changing the oil in a car, most people do on a regular basis. 
So with the fixtures, regular maintenance it an excellent practice, if you want the fixtures to last. 
So what is the maintenance for the fixture? 

 
 
 
 

Clean the light! 

 

Turn off the led profile spotlight. 
Using a small vacuum cleaner, suck the dust and “fur balls” out. 
Do not use a can of co². That will just blast the dust and dirt everywhere! 
The front lens should be cleaned so the light output is maintained. 
The shutter blades sometimes require cleaning as well. 
With  the  led  profile  spotlight  turned  off,  use  only  a  moist  lint-free  cloth.  Never  use  alcohol  or 
solvents to clean the fixture. 
Never spray anything onto the fixture at the front or in any place on the fixture. 

 
 
 
 
 
 
 
 
 

 

 
 
 

 

Содержание Luxe Cannon 600 Z IP

Страница 1: ... Leko Cannon LED 300 CW WW User Manual IP65 Luxé Cannon 600 Z IP VW ...

Страница 2: ...ure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal proce...

Страница 3: ...e or cord of this luminaire is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard Please pay attention below warnings before using this fixture ...

Страница 4: ...h nice outlook The fixture is designed and manufactured strictly following CE RoHS standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for operation And it is applicable for large scale live performances theater studio nightclubs and discos The Leko Cannon 300 adopts 1PCS 600W COB LED available for cool white warm whi...

Страница 5: ... reflects greater than 95 of visible light Input Voltage AC100 240V 50 60Hz Beam Angle 15 to 30 Zoom Function Auto zoom by DMX Shutter controlled by DMX auto cutting to any shapes Die casting aluminum housing design 4 kinds of dimming curve Dimming Frequency 500HZ 25000HZ optional High quality optical system glass aspherical 17 DMX channels Control Protocol RDM DMX Auto run and Master Slave contro...

Страница 6: ...CONNECTIONS Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connection with DMX terminator 4 ...

Страница 7: ... DMX Input 3 Pin XLR DMX512 Out DMX512 In 3 Pin XLR 3 Pin XLR 1 Ground 2 Data 3 Data COMMON DMX DMX 120Ω Pin2 Pin3 DMX INPUT DMX OUTPUT POWER IN ...

Страница 8: ...ature Ø 2 kinds of running model n External control mode Slave model u DMX 512 controller control 2 kinds channel modes u Master salve model control auto match the signal from controller and the Master light no need to set by menu n static mode Master model u It can fix any color without the controller also work this color with strobe Ø Non linear dimmer and linear dimmer n The speed of dimmer can...

Страница 9: ...light or different time of them connect to the controller In this case you can change value of the controller for example push 20 to 0 and back to 20 then it can be synchronization 2 Due to crystal frequency of different lights are not the same exactly so it may not be synchronization after long time 3 If need to keep synchronization for long time there are two ways to do so A Using the controller...

Страница 10: ...erature Mode M WP M stand for stand Master WP stand for White Point DMX Menu Enter DMX mode 1 If you are in DMX mode the main menu will turn into DMX menu automatically after 5 seconds 2 Menu of DMX address DMX mode will turn into DMX menu automatically after 5 seconds DMX Menu Operation ...

Страница 11: ...l Same as above Control the motor 7 2 Motor Control Remarks The meaning of below menu data are completely the same as DMX channels data As left and right are relative concept so the left point and right point of shutter separately use alphabet A B for instead Menu Data Function Remark Reset Push Confirm to reset M1 0 255 M1 M2 Position control Push Confirm to edit M2 0 63 M1 M2 Angle control Over ...

Страница 12: ... 255 M7 M8 Angle control Refer to M2 Auto Zoom 0 255 Auto Zoom Focus adjustment 0 255 Focus adjustment Gobo 0 127 Gobo angle 128 191 Gobo rotation 192 255 Gobo rotation reverse Iris 0 255 Iris Macro 0 63 No function 64 255 Built in shape cutting 7 3 Status Software Name of software Version Version Temperature Show the current temperature of the fixture DMX Status Show OK Slave with DMX signal NONE...

Страница 13: ... the protect temperature 45 95 Increase or decrease with data of 5 Backlight Adjust the Backlight brightness 10 100 Increase or decrease with data of 5 Backlight Timeout Set the screen protect time screen protect or screen protect after 5 60 seconds Increase or decrease with data of 5 Load Factory Settings Reset DMX CHANNELS 17CH 8 ...

Страница 14: ...l 5 0 63 M1 M2 Control straight up and down by channel 3 64 127 M1 M2 Angle adjustment big data big angle 128 191 M1 M2 back to original position 192 255 M1 M2 Reverse angle adjustment big data big angle 6 0 255 M3 M4 position control 7 M3 M4 position control refer to channel 4 8 0 255 M5 M6 position control 9 M5 M6 position control refer to channel 4 10 0 255 M7 M8 position control 11 M7 M8 posit...

Страница 15: ...nge the fixtures without any instruction by the manufacturer or the appointed repairing agencies It is not in warranty range if there are any malfunctions from not following the user manual to operate or any illegal operation like shock short circuit electronic shock lamp broke etc INSTALLATIONS For added protection mount the fixtures in areas outside walking paths seating areas or in areas were t...

Страница 16: ... not a secondary safety point A secondary safety point is any point that will adequately hold the led profile spotlight if the C clamp or half cheesboro fails Then the safety cable would be the backup and stop the fixture from falling to the ground So do NOT fix the safety cable to the same place that the C clamp is attached Safety Clamp Safety Cable 11 Floor Projection ...

Страница 17: ... the fixtures to last So what is the maintenance for the fixture Clean the light Turn off the led profile spotlight Using a small vacuum cleaner suck the dust and fur balls out Do not use a can of co That will just blast the dust and dirt everywhere The front lens should be cleaned so the light output is maintained The shutter blades sometimes require cleaning as well With the led profile spotligh...

Отзывы: