4.  Ìàíæåòà ïîâèííà ù³ëüíî îáëÿãàòè ðóêó. Çàô³êñóéòå 
ìàíæåòó, çàñò³áíóâøè ëèïó÷êó. ßêùî º íåîáõ³äí³ñòü, 
ïîïðàâòå ìàíæåòó.  

5.  Ïîêëàä³òü ðóêó ïàö³ºíòà íà ñò³ë. Ðóêà ïîâèííà áóòè 
ðîçñëàáëåíîþ, äîëîíåþ âãîðó. Ïåðåêîíàéòåñü, ùî 
ìàíæåòà ðîçòàøîâàíà íà ð³âí³ ñåðöÿ. 

6.  Â³çüì³òü ìàíîìåòð â îäíó ðóêó, 
ïîâåðí³òü öèôðàìè äî ñåáå. ³çüì³òü 
ãðóøó â äðóãó ðóêó. Çàêðèéòå 
ïîâ³òðÿíèé êëàïàí, ðîçòàøîâàíèé 
íà ãðóø³, ïîâåðíóâøè ãâèíò çà 
ãîäèííèêîâîþ ñòð³ëêîþ.

7.  Ùîá íàêà÷àòè ìàíæåòó, ð³âíîì³ðíî ñòèñêàéòå ãðóøó 
â ðóö³. Íàêà÷óéòå ìàíæåòó, äîêè ñòð³ëêà ìàíîìåòðà 
íå ïåðåéäå íà 20-30 ìì.ðò.ñò. âèùå ÇÂÈ×ÀÉÍÎÃΠ

ÑÈÑÒÎ˲×ÍÎÃÎ òèñêó. 

ÏÎÏÅÐÅÄÆÅÍÍß:

 Í²ÊÎËÈ ÍÅ ÍÀÊÀ×ÓÉÒÅ ÌÀÍÆÅÒÓ 

Á²ËÜØ Í²Æ 280 ìì ðò. ñò. ÖÅ ÌÎÆÅ ÏÐÈÇÂÅÑÒÈ 
ÄÎ ÒÐÀÂÌÓÂÀÍÍß ÏÀÖ²ªÍÒÀ ÀÁÎ ÏÎØÊÎÄÆÅÍÍß 
ÏÐÈËÀÄÓ. 

8.  Ïîâ³ëüíî â³äêðèéòå ïîâ³òðÿíèé 
êëàïàí, ïîâåðòàþ÷è ´âèíò ïðîòè 
ãîäèííèêîâî¿ ñòð³ëêè. Âèïóñêàéòå 
ïîâ³òðÿ ç³ øâèäê³ñòþ 2-4 ìì.ðò.ñò. â 
ñåêóíäó. 

9.  Óâàæíî ñëóõàéòå  òîíè ³ ñïîñòåð³ãàéòå çà ñòð³ëêîþ 
ìàíîìåòðà. Êîëè Âè ïî÷óºòå ïåðøèé ÷³òêèé çâóê, öå 
çíà÷åííÿ º âåëè÷èíîþ ÑÈÑÒÎ˲×ÍÎÃÎ àðòåð³àëüíîãî 
òèñêó. 

10.  Ïðîäîâæóéòå âèïóñêàòè ïîâ³òðÿ ç³ øâèäê³ñòþ 
2-4 ìì ðò. ñò. â ñåêóíäó.   Êîëè äîñÿãíóòî çíà÷åííÿ 
IJÀÑÒÎ˲×ÍÎÃÎ àðòåð³àëüíîãî òèñêó, çâóê áèòòÿ 
ïåðåñòຠáóòè â³ä÷óòíèì. 

11.  Â³äêðèéòå ïîâ³òðÿíèé êëàïàí, ïîâåðòàþ÷è ´âèíò 
ïðîòè ãîäèííèêîâî¿ ñòð³ëêè ùîá ïîâí³ñòþ âèïóñòèòè 
ïîâ³òðÿ ç ìàíæåòè. Çàïèø³òü ïîêàçíèêè. 

Содержание 700

Страница 1: ...INSTRUCTION MANUAL ANERIOD BLOOD PRESSURE KIT p 2 11 12 21 model 700 700...

Страница 2: ...OF CONTENTS Unit Assembly 3 How to Take a Reading 4 Quick Reference Guide 8 Care and Maintenance 9 Warranty 10 Technical specifications 10 UNIT ASSEMBLY Lay out the parts as pictured on the next page...

Страница 3: ...D COR RECTLY AND SECURELY FAILURE TO DO SO MAY RESULT IN INJURY OR AN INCORRECT READING 2 Locate brachial artery by placing two fingers 2 cm above the bend of the elbow on the inside of the arm 3 Plac...

Страница 4: ...ABOVE normal SYSTOLIC reading CAUTION DO NOT INFLATE THE CUFF ABOVE 280 mmHg YOU MAY INJURE THE PATIENT OR DAMAGE THE INSTRUMENT 8 Slowly open the air release valve by turning it coun ter clockwise Re...

Страница 5: ...RE AND MAINTENANCE To protect your unit from damage please AVOID washing or moistening the cuff or dropping the gauge Your new blood pressure unit has been carefully checked to assure reliability and...

Страница 6: ...tative of the sales organization and its stamp and safety of the packaging TECHNICAL SPECIFICATIONS Weight 385 g Size 170 x 120 x 70 mm Storage temperature 5 to 35 Humidity 80 relative humidity maximu...

Страница 7: ...12 13 M 700 13 14 18 19 20 20 1 2 25 4 40 6...

Страница 8: ...14 15 1 2 2 3 1 2...

Страница 9: ...16 17 4 5 6 7 20 30 280 8 2 4 9 10 2 4 11...

Страница 10: ...18 19 2 3 1 5 2 3 30 1 2 20 30 3 4 2 4 1 2 3...

Страница 11: ...20 21 18 385 170 120 70 5 35 80 0 35 0 300 2 3 15 25 6 34 46 3 75 1 2 25 4 40 6 3 4 5...

Отзывы: