Gamko FLEXBAR X/VS20 Скачать руководство пользователя страница 12

Flexbar

21-1-2009

edda

Algemene installatie instructie

m

o

d

if

ic

a

ti

o

n

s

destination

Gamko Holding BV

Mon Plaisir 75

4879 AL Etten-Leur

Tel.(0)76-5087500

The Netherlands

name

drawing nr.

draftsman

date

196169

1

02/09 DMX + CELS

5611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

02/09 DMX + CELS

5611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blad 12 van 13

Service

49

48

F

DETAIL F

50

006130053

*

*

Reed switch
008110167

*

51

52

Reed switches

1

2

3

Jumper

4

53

012100509

24V LED

24V CELS+

heating wire

24VDC CELS

24VDC heating wire

24VDC RGB LED

230VAC

Connect heatingwire parallel to 24V powersupply
- Flexbar without CELS: use new powersupply
- Flexbar with CELS: use CELS powersupply

- Do NOT use RGB LED powersupply!

1 Place magnet in hole opposite of hinge

top of magnet must be flush with door

2 oppervlak ontvetten
3 plak

read switch mbv VHB tape in oversteek

4 reed switch uitlijnen met scharniergat (zie illustratie)

(zorg ervoor dat de magneet uitlijnt met de    )

1 Connect reed switches in series
2 Make sure the gap between the reed switches and the
magnet is not too big

if necessary place extra washers between hinge and door

3

Connect reed switches in the electrobox

on pin14 (digital output) and together with
the temperature sensor on pin12
4 Remove jumper on back of display

Ergonomic light - production
(white light behind solid doors with doorswitch)

Place X/EP02 to segment, align top and front and fix using
4x40mm (012100509) screws in the 4 pre-punched holes

Make sure the screw heads end up flush with side

Connecting heating wire (to

prevent condensation)

Ergonomic light - production
(white light behind solid doors with doorswitch)

align with hinge hole

align

Ergonomic light - installation
(white light behind solid doors with doorswitch)

Temperature

sensor

Placing X/EP02

g

o

o

d

to

o

 b

ig

 Ergonomic light - installation
(white light behind solid doors with doorswitch)

GB

Содержание FLEXBAR X/VS20

Страница 1: ...ents next to X MU or X VS20 4 legs on open storage segments X OS 3 legs on all other segments pull tape to open box 4 9 10 21 22 27 28 33 X MU X 1HB X VS20 X VS00 Settings troubleshooting X ACLED1 Coloured Equal LED 006030694 013060019 Changing direction door Postmix column on X 1HB 1 3 34 39 X TB trafobox 41 48 Connecting heating wire to prevent condensation on frame Connecting ergonomic light X ...

Страница 2: ...s through cable duct and down behind machinefront 1 Place trafobox bracket over condensor 2 Place trafobox Neatly tue up excess cables Check if all accessoires are working properly Lead cables through hole Connect trafobox Plug in connectors for LED and DMX in the trafobox Plug in connectors for CELS and 24V in the junctionbox behind the machinefront Recommended order First segment left of X MU an...

Страница 3: ...essoires such as LED CELS or heating wire remove 1 horizontal bottle drawer 2 drawer slides 3 machinefront and 4 cross beam 5 Remove screws from evaporator cover 6 Pull out unit approximately halfway Mount trafobox behind electrobox Connect trafobox Slide unit back in place X X Recommended order First endpanels Do NOT couple segment left of X 1 yet 2nd 1th 2nd 1th place sealing tape between X EP a...

Страница 4: ...met in slider profile Remove cap s 1 lead cables through the tubes into the segment 2 then out through slider profile 3 and back in through the previous made hole Mount cable duct profile Couple segments left of X 1HB Seal all holes connecting cold and warm areas holes marked with S Plug in connectors for LED and DMX in the trafobox Plug in connectors for CELS and 24V in the junctionbox behind the...

Страница 5: ...ulation and place grommet 2 For LED place bracket provided with trafobox 3 Place trafobox and lead cables through grommet 4 Seal hole Connect trafobox Click conenctors in bracket Plug in connectors for LED in the bracket Plug in connector for DMX in trafobox Plug in connectors for CELS and 24V in the junctionbox behind the machinefront Recommended order First segment left of X VS and endpanels 1th...

Страница 6: ...ers are blocked when closed 1 When equippedwith electrical accessories such as LED CELS or heating wire Lead wires through cable duct and out the cornerpiece 2 Place external trafobox Recommended order First both segments in between X VS00 is to be placed 1th 1 determine to which side the copper and electrics will leave the bar bend and soler the copper 2 remove shelf support rails from X VS00 whe...

Страница 7: ...3 Place cable duct covers horizontaly according to illustration above 4 Connect line cord in socket tie up cord to prevent loss during placement 5 Slide bar in place 6 Adjust feet to level out bar and or jack up bar against top Attention cable duct covers must remain accessible 7 Place caps to cover all coupling holes inside segments 8 Place caps to cover all feet adjuster holes Place shelf suppor...

Страница 8: ...X TBMU 1 X TBMU 2 X TBMU 3 X TBMU 4 X TBMU 5 X 1HB 1 X TB1 1 X TB1 2 X TB1 3 X TB1 4 X TB1 5 X VS20 1 X TBVS 1 X TBVS 2 X TBVS 3 X TBVS 4 X TBVS 5 X VS00 X TBEX 1 X TBEX 2 X TBEX 3 X TBEX 4 X TBEX 5 48 Heating wire see GB CELS LED white LED RGB CELS LED RGB CELS LED white Machine evaporator segments Flexbar without CELS use new powersupply Flexbar with CELS use CELS powersupply Do NOT use RGB LED ...

Страница 9: ...0 1 DMX address 0 0 1 Controller Gamko example Driver Bar 2 slave 0 example Driver Bar 3 slave 1 External DMX device master DMX in DMX out DMX in DMX out DMX in DMX out DMX in DMX out DMX in DMX out RJ45 RJ45 Ethernet patch cable Cat5e XLR RJ45 connection cable 008110192 Mode switch see list Default 5 Gamko controller mode X ACLED1 A mode 4 manual colour lapse master controller controls colour and...

Страница 10: ... ports cablecut when all of the above hasn t solved the problem replace part of cable harness Colour within one segment differs one or more colour within the LED is broken but still closes the power circuit interchange drawers or LED s to determine which LED s are malfunctioning and replace if necessary short circuit in a cable harness possible cut by screw replace cable harness drill hole O12 for...

Страница 11: ... screws from evaporator cover 6 Place unit bracket to remove unit 7 Disconnect main powersupply connector and pull out unit 8 Drill a hole Ø85mm in center of X 1HB at 355mm from front 9 Break out knock out pattern left or right and cut away insulation to make space for post mix tube 10 clamp up tube and reassemble X 1HB On installation place X TP00 or X TP02 between segments using double sided tap...

Страница 12: ...en met scharniergat zie illustratie zorg ervoor dat de magneet uitlijnt met de 1 Connect reed switches in series 2 Make sure the gap between the reed switches and the magnet is not too big if necessary place extra washers between hinge and door 3 Connect reed switches in the electrobox on pin14 digital output and together with the temperature sensor on pin12 4 Remove jumper on back of display Ergo...

Страница 13: ...ELS 55 Keyswitch 013050129 Cuff round 013050129 Retaining nut 013050129 Relais block 013050130 2x improved assembly order keyswitch lock relais blocks wiring diagram relais blocks CELS keyswitch ATTENTION Red black twincable connected differently on drawer segment Make sure cable transit hole is sealed CELS Assembly keyswitch CELS Connecting keyswitch CELS connecting storagesegments to 24V to junc...