background image

WWW.GAMAINC.COM

Page 4 REV B 03/09/20

Troubleshooting

All remote-control systems shipped by GAMA Electronics are 100% functionally tested just prior to shipment. 

If your RF remote control system does not work out of the box, stops working or functions intermittently please take the 

following steps to resolve common issues. Please note that you must be 2-3 feet away from the receiver when operating 

the remote control. Operating within 2-3 feet may result in no operation or intermittent operation.

1. Replace the A23 12V Battery in the transmitter

·

The remote control can activate during shipping and drain the battery that is installed in the control. We 

send a replacement battery with the system if this occurs.

2. Check the voltage supply at the receiver

·

The receiver is designed to function at 10-15VDC. Voltage on the (+) and (-) terminals on the control 

should be within this range. 

3. Reprogram the remote control

·

If the system is non-functional try to reprogram the remote control. The program may not have taken 

during the programming process or the program button may have been pressed. If the program button is 

pressed the memory of the remote controls programed to the receiver are erased.

4. Listen and look for functionality on the receiver.

·

The LED that is used for programming the system will illuminate when the receiver is activated. You will 

also hear a “click” when the internal relays engage. If you can see the LED illuminate and you hear the 

relay “click” the issue is most likely in the wiring or device being controlled.

RF340-400APR

Instruction Manual

Содержание RF340-400APR-WPTX

Страница 1: ...on switches mounted on the receiver This permits operation of the control without using a transmitter The control can be configured for either momentary or latching operation In the momentary mode the motor will operate as long as the buttons are held down In the latching mode pressing either button will start the motor and pressing the button a second time will stop the motor The auxiliary switch...

Страница 2: ...n the transmitter and verify that the red program LED extinguishes and then illuminates blinks once Proceed to Step 5 4 To configure the receiver for latching output press and release the DOWN button on the transmitter and verify that the red program LED extinguishes and illuminates blinks once 5 Repeat previous step for additional transmitters that will operate with this particular receiver The r...

Страница 3: ...WWW GAMAINC COM Page 3 REV B 03 09 20 RF340 400APR Instruction Manual Wiring Diagram RF12V1PR ASL GAMA Electronics Inc www gamainc com M1 M2 12V 12V PROGRAM M1 M2 12V 12V Programming Switch ...

Страница 4: ...ery with the system if this occurs 2 Check the voltage supply at the receiver The receiver is designed to function at 10 15VDC Voltage on the and terminals on the control should be within this range 3 Reprogram the remote control If the system is non functional try to reprogram the remote control The program may not have taken during the programming process or the program button may have been pres...

Отзывы: