100%
255 = FF
STOP
50 to 99%
129 to 254
25 to 0.1 Rpm counterclockwise spin
50%
128
STOP
1 to 49%
0 to 127
0.1 to 25 Rpm clockwise spin
0%
0
STOP - at position set by indexing fader
FADER %
HEXADECIMAL
FUNCTION
Speed - channel 2
Index / Position of gobo
1 to 100%
0 to 255
Index position (8 bit) 0 - 359 degrees
0%
0
Continuous rotation as set by speed channel
76 to 99%
193 to 254
0.1 to 25 Rpm counterclockwise
75%
191 to 192
STOP
51 to 74%
129 to 190
25 to 0.1 Rpm clockwise spin
50%
128
STOP
0 to 49%
0 to127
Index 0 to 359 degree at 5 Rpm shortest route
Pag e 2 of 6
•
•
•
100%
255 = FF
STOP
All indexing takes place at 5 Rpm.
MODE 2
OPERATION -- MODE SWITCH = 2 -- 2 CHANNEL OPERATION
•
•
Speed - channel 1
1. Speed and direction of continuous spin
•
•
•
•
If the indexing channel is set to zero, then the gobo will continuously rotate according to the setting of the speed channel.
In Index Mode (channel 2 is set above 1%), the gobo will take the shortest route to its position.
The speed of indexing is set by channel 2 and for index mode, the speed-control-channel stop positions are not used.
MODE 1 OPERATION -- MODE SWITCH = 1 -- 1 CHANNEL OPERATION
FADER %
HEXADECIMAL
FUNCTION
FADER %
HEXADECIMAL
FUNCTION
Speed and position control on a single fader
Set DMX address - This number will correspond to channel control for the rotator
The indexing gobo is controllable according to the following table:
Separate speed and position control
Set DMX address
The indexing gobo is controllable according to the following table:
12/06
0% is full speed indexing
50
100% (full) is full indexing
% is 0.1 rpm indexing
.
•
•
•