Galvo Shed GVO 2315 Скачать руководство пользователя страница 5

If you choose to vary from these instructions your warranty will be impaired

5

DIAGRAM 1

STEP 4 

BACK WALL

Join the three sheets 

C

 together with 2 fixings through the overlapping 

ribs, making sure the ends of the sheets are flush.
Cap the sheeting with the 2255mm 'U' channels 

F

.

Fix the channels through the end ribs and every second rib in between.
Make sure you put at least one fixing per sheet up through the 
underside of the channel into the pan of the sheet.

STEP 5 

ROOF

Join the three sheets 

 together, same as the back. Cap the sheeting with the 2255mm 

'U' channels 

F

. Fix the channels at every second rib but not the corners at this stage.

Place the short flange of the first 'L' flashing 

K

 on top of the rib at one end. Make sure 

the ends are flush with the sheeting (diagram 1) and put one fixing in the centre to hold 
the 'L' flashing. Fix the corners through the channels and one more 
between the corner and the centre fixing. Perform the same at the 
other end. Five fixings each 'L' flashing.

GALVO TIP

Put extra fixings in for  

high wind areas, particularly  

on the underside.

YOU WILL NEED

3 x 1830mm x 780mm sheets

2 x 2255mm 'U' channels

2 x 1830mm ‘L’ flashings

D

F

K

YOU WILL NEED

3 x 1830 x 780mm sheets

2 x 2255mm 'U' channels

C

F

F

F

C

F

F

K

K

D

Содержание GVO 2315

Страница 1: ...rewdriver or riveter Tape measure Ladder Non slip gloves good shoes and goggles A set of helping hands CALL 0508 454 873 for an installer near you Some parts have sharp edges and should be handled ver...

Страница 2: ...of 2 x 793mm U channels door spacers 2 x Z Door braces BUILDING YOUR SHED The basic task is to join the sheets together to form your panels and fix channels to the top and bottom of these panels They...

Страница 3: ...e U channels and fixing it to the sheet ribs and the side U channels Attach the hinges N approx 150mm from the top and bottom of the door through the U channels The fixings should be centred on the si...

Страница 4: ...or ADDITIONAL INFORMATION Channels will come short of the ends of the sheeting by 10 15mm on all panels PADLOCK KEEPER ASSEMBLY KEEPER WASHER RIVET CHANNELS The higher side of the channel goes to the...

Страница 5: ...ck Cap the sheeting with the 2255mm U channels F Fix the channels at every second rib but not the corners at this stage Place the short flange of the first L flashing K on top of the rib at one end Ma...

Страница 6: ...at the top overlapping in the centre behind the padbolt If you have a locking T handle you will have to run the Z s the opposite way to the diagram Rivet the Z s at the ends and in the centre of the...

Страница 7: ...l of the front and the back walls 10mm more than the overhang Fix beside every second rib You will not need to worry about these fixings leaking as any water seeping through these fixings will end up...

Страница 8: ...nt or act of God including weather b The warranty shall cease and the Supplier shall thereafter in no circumstances be liable under the terms of the warranty if the workmanship is repaired altered or...

Отзывы: