background image

If you choose to vary from these instructions your warranty will be impaired

6

5

CHANNELS

Channels will end 15-20mm 

short at tops of end walls 

and 10-15mm at bottoms.

STEP 6 

END WALLS

Cap the sloping sheets 

E

 with the 735mm 'U' channels 

G

.

Fix the channels through the end ribs and every second rib in between. 
Make sure you put at least two fixings up through the underside of the channel into the 
pan of the sheet. 
Repeat for other side wall with opposite slope.

STEP 7 

DOOR BRACES

The door braces can be fitted now or after you have assembled your shed. 
Tuck one end of the 'Z' between the bottom channel of the inside of the 
door and the sheet. Do the same at the top, overlapping in the centre 
behind the padbolt. If you have a locking 'T' handle you will have to run 
the 'Z's the opposite way to the diagram.
Rivet the 'Z's at the ends, and in the centre of the channel it is tucked 
under, and through the overlap in the centre. Two or three more fixings will 
be required through the door sheeting into the 'Z', but they will need to be 
riveted through from the outside of the door for a neater appearance.
You may need to cut or bend the flange at the bottom and the top of the 
'Z' if it catches on the door jamb when opening or closing (diagram 1).

AFTER

DIAGRAM 1
BEFORE

YOU WILL NEED

2 x 1830mm - 1770mm sidewalls 

2 x 735mm 'U' channels per side

E

G

G

G

E

YOU WILL NEED

2 x 'Z' Door braces

Fixings

O

N

Содержание GVO 1508

Страница 1: ...iveter Tape measure Ladder Non slip gloves good shoes and goggles A set of helping hands CALL 0508 454 873 for an installer near you Some parts have sharp edges and should be handled very carefully We...

Страница 2: ...the code on the front page 1 x 1770 x 780mm door sheet 1 x narrow 1830 x 715mm sheet for front wall beside door 2 x 1830 1770mm sloping sheets side walls 1 left 1 right 2 x 1770mm U channels for door...

Страница 3: ...n the centre of the door sheet slipping it under the two side U channels and fixing it to the sheet ribs and the side U channels Attach the hinges N approx 150mm from the top and bottom of the door th...

Страница 4: ...ou use an 8mm shackle diameter padlock on these pad bolts anything smaller may create security issues ADDITIONAL INFORMATION Channels will come short of the ends of the sheeting by 10 15mm on all pane...

Страница 5: ...sheeting with the 1515mm U channels F Fix the channels at every second rib but not the corners at this stage Place the short flange of the first L flashing K on top of the rib at one end Make sure the...

Страница 6: ...m channel of the inside of the door and the sheet Do the same at the top overlapping in the centre behind the padbolt If you have a locking T handle you will have to run the Z s the opposite way to th...

Страница 7: ...l of the front and the back walls 10mm more than the overhang Fix beside every second rib You will not need to worry about these fixings leaking as any water seeping through these fixings will end up...

Страница 8: ...nt or act of God including weather b The warranty shall cease and the Supplier shall thereafter in no circumstances be liable under the terms of the warranty if the workmanship is repaired altered or...

Отзывы: