Product Installation Guideline
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and in accordance with the
national and local regulatory water requirements. Water and/or electrical supply conditions must also comply to the applicable National
standards. Failing to comply with these provisions shall void the product warranty and may affect the performance of the product.
1. Fit face plate assembly
Fit the face plate assembly into the panel.
Secure face plate with supplied M6 nuts
and spring washers.
2. Connect water supply
Connect water supply to correct inlet as
shown, use a suitable thread sealing
compound making sure there are no
obstructions or blockages to the pipework.
Note: Water supply should be flushed
before fitting. The use of in-line strainers is
highly recommended.
3. Testing
Once fitted and test body unit for leaks
and correct operation.
TROUBLESHOOTING
PROBLEM
CAUSE
RECTIFICATION
Face plate does not sit flush on panel
surface.
Mounting holes not drilled correct size or PCD is
incorrect or the panel is not flat.
Re-drill as per rough in details
Replace or straighten panel.
The desired mixed water temperature
cannot be obtained.
Hot and cold water supply are fitted to the wrong
connections.
Re-fit the valve with hot and cold water
supply to the correct connections.
Waterway contains debris preventing correct
operation.
Water supply issue
– contact facility
management.
The valve will not shut off.
Cartridge contains debris.
Clean or replace cartridge.
SERVICE AND MAINTENANCE
1. Disconnect water line
Turn of the water supply and turn on the
tap handle to release any pressure in the
lines.
Disconnect cold,hot & outlet water
connections.
2. Remove face plate assembly
Unscrew face plate M6 screws from studs
at rear panel.
Pull out face plate body assembly from the
panel.
3. Remove grub screw
Unscrew grub screw from the body
assembly.