Product Installation Guideline 

INSTALLATION 

 
IMPORTANT:  Galvin Specialised products must  be  installed  in accordance  with  these  installation  instructions  and  in accordance  with  the 
national  and  local  regulatory  water  requirements.  Water  and/or  electrical  supply  conditions  must  also  comply  to  the  applicable  National 
standards. Failing to comply with these provisions shall void the product warranty and may affect the performance of the product. 
 

 

 

 

1. Fit face plate assembly 

 

Fit the face plate assembly into the panel.  

 

Secure face plate with supplied M6 nuts 
and spring washers. 

 

2. Connect water supply 

 

Connect water supply to correct inlet as 
shown, use a suitable thread sealing 
compound making sure there are no 
obstructions or blockages to the pipework. 

 

Note: Water supply should be flushed 
before fitting. The use of in-line strainers is 
highly recommended. 

3. Testing 

 

Once fitted and test body unit for leaks 
and correct operation. 

 

TROUBLESHOOTING 

PROBLEM 

CAUSE 

RECTIFICATION 

Face plate does not sit flush on panel 
surface. 

Mounting holes not drilled correct size or PCD is 
incorrect or the panel is not flat. 

Re-drill as per rough in details 

Replace or straighten panel. 

The desired mixed water temperature 
cannot be obtained. 

Hot and cold water supply are fitted to the wrong 
connections. 

Re-fit the valve with hot and cold water 
supply to the correct connections. 

Waterway contains debris preventing correct 
operation. 

Water supply issue 

– contact facility 

management.  

The valve will not shut off. 

Cartridge contains debris.  

Clean or replace cartridge. 

 

SERVICE AND MAINTENANCE 

 

 

 

1. Disconnect water line 

 

Turn of the water supply and turn on the 
tap handle to release any pressure in the 
lines. 

 

Disconnect cold,hot & outlet water 
connections. 

 

 

2. Remove face plate assembly  

 

Unscrew face plate M6 screws from studs  
at rear panel. 

 

Pull out face plate body assembly from the 
panel.

 

3. Remove grub screw 

 

Unscrew grub screw from the body 
assembly. 