Galvin Specialised SHWR-DV-01 Скачать руководство пользователя страница 2

 

 

 

 

Version 17 February 2017 Page 

2

 of 

3

 

Product Installation Guideline 

INSTALLATION 

 
IMPORTANT:  Galvin  Specialised  products  must  be  installed  in  accordance  with  these  installation  instructions  and  in  accordance  with 
AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable 
National and/or State standards. Failing to comply with these provisions shall void the product warranty and may affect the performance of 
the product. 

 

 

 

 

1. Fit Body assembly 

 

Secure body with mounting bracket as 
shown, so it is protruding past the 
finished wall between 8 and 11mm. 

 

Body bracket can be secured with 
suitable fixings through the two slots. 

 

It is critical that the centre line of the fitted 
body is perpendicular to the finished wall 
to ensure correct fitment of the faceplate 
and flange. 
 

2. Connect water supply 

 

Connect water supply to correct inlet as 
shown, use a suitable thread sealing 
compound making sure there are no 
obstructions or blockages to the pipework. 

 

Note: Water supply should be flushed 
before fitting. The use of in-line strainers is 
highly recommended. 

3. Fit face plate & flange 

 

Fit O ring to flange groove. 

 

Slide shower face plate on to body. 

 

Tighten flange to secure. 

 

Adjust bracket nuts to ensure face plate is 
fully tightened & thighten lock nuts. 

 

 

 

 

4. Fit the control knob 

 

Fit the control knob, ensure when the knob 
is set to ‘fixed shower’ the handle is facing 
down as shown and when rotated the 
handle matches the lines on the face 
plate.  

 

Secure the handle with supplied tamper 
proof screw. 

5. Fit grub screw to flange 

 

Fit grub screw in to flange in either hole 
provided. Choosing the hole that isn’t 
blocked by the bracket. Tighten grub 
screw to 1.5nm. 

 

6. Testing 

 

Once fitted turn on water and check for 
leaks and correct operation.

  

 

TROUBLESHOOTING 

PROBLEM 

CAUSE 

RECTIFICATION 

Face plate does not sit flush on 
wall 

Diverter not mounted perpendicular to wall 

Remove and re-mount so the body is 
perpendicular to finshed wall 

Water flow does not match 
faceplate markings 

Handle not aligned correctly to faceplate 

Remove tamper proof screw and roate 
control knob until matching faceplate 
re-tighten tamper proof screw. 

Outlet on body not connected to the correct service outlet 

Change outlet connection on body 

Содержание SHWR-DV-01

Страница 1: ...but is able to withstand heavy knocks Bevelled edges for maximum tight fixing This item is designed for panel wall installation wall thickness up to 20mm TECHNICAL DATA Inlet connections BSP Female 1...

Страница 2: ...upply should be flushed before fitting The use of in line strainers is highly recommended 3 Fit face plate flange Fit O ring to flange groove Slide shower face plate on to body Tighten flange to secur...

Страница 3: ...ility and fitness for a particular purpose Galvin Engineering Pty Ltd products are covered under our manufacturer s warranty available for download from www galvinengineering com au Galvin Engineering...

Страница 4: ...Client Project TITLE Drg No SHOWER DIVERTER VALVE Scale All dimensions in mm All angles 90 unless stated 3rd REVISION HISTORY REV DATE DESCRIPTION BY CHKD 3 02 11 2016 Graphics control size updated P...

Страница 5: ...to the valve body to hold it in position on the wall panel whilst securing the bracket with screws Adjustment of the bracket position on the valve body may be necessary to move the valve forwards or...

Страница 6: ...BE REPRODUCED COPIED OR USED WITHOUT PRIOR AGREEMENT OF WALLGATE LTD A3 Limits unless stated 0 25mm sheetmetal 0 10mm machined 2 00mm pattern 5 00mm moulded c O 2016 Copyright Model Client Project TIT...

Страница 7: ...ORTANT NOTE THE WATER SUPPLY MUST BE FLUSHED THROUGH TO REMOVE ANY DEBRIS PRIOR TO CONNECTION TO THE VALVE ENSURE PLUMBING THREAD SEALENTS IF USED ARE NOT APPLIED EXCESSIVELY WHEREBY DAMAGE TO THE VAL...

Отзывы: