Galvin Specialised Ezy-Wash TF85-J Скачать руководство пользователя страница 4

 

 

 

 

Version 2, 4 August 2017, Page 

4

 of 

5

 

 

 

5.  Secure support rod 

1.  Fasten support rod securely against CP 

riser. 

2.  Tighten compression nut on wall bracket 

to secure the support rod. The rod is now 
rigid.

 

6.  Test unit  

  Once all fittings have been tightened 

securely, connect the unit to the mains 
water. 

 

Turn on water and test the unit for any 
leaks.

 

WARNINGS 

For optimum performance it is recommended that the isolation or mains taps are turned off whilst the unit is 
not in use (overnight etc.), so that the unit is not under mains pressure when unsupervised.  Flood damage 
may occur if a failure occurs whilst the unit is under mains pressure (warranty is void in this instance). 
 
Galvin Specialised recommends that the handpiece is periodically serviced by a qualified plumber.  

 

         IMPORTANT:

  

To seal the hose this unit uses Loctite 577 which is a thread sealant approved for use with potable water 
(AS/NZS 4020). If hose is to be removed for maintainance purposes, reseal the joints with Loctite 577, or 
an equivalent sealant compliant with AS/NZS 4020. Do not use thread tape to seal the hose connections, 
as this may cause the hose nut to become loosened over time and leak.

 

 
 

Содержание Ezy-Wash TF85-J

Страница 1: ...gnifies hot water only If water other than hot is used e g cold then appropriate identification buttons will need to be purchased to replace those supplied on the standard unit TECHNICAL DATA Inlet Swivel spindle Outlet Aerator Headworks TF85 J Jumper Valve TF85 C Ceramic Working Pressure Range kPa Min 100 Max 500 Working Temperature Range C TF85 J Min 5 Max 65 TF85 C Min 5 Max 65 Nominal Flow Rat...

Страница 2: ...plicable national and or state standards Failing to comply with these provisions shall void the product warranty and may affect the performance of the product New Installation The following instructions must be followed in all respects and read in conjunction with installation and operation instructions supplied with new pre rinse unit 1 Fit pot filler and riser Remove protective cap from upper ri...

Страница 3: ...age any o rings Remove pre rinse unit body from hub mounted assembly if required 3 Fit pot filler and riser Remove protective cap from upper riser spindle Fit the upper riser to the lower riser ensure the sealing o rings are inside the spindle Tighten with new supplied grub screw It is critical that the grub screw point locates accurately into hole recess of mating part Failure to do so may result...

Страница 4: ...ght etc so that the unit is not under mains pressure when unsupervised Flood damage may occur if a failure occurs whilst the unit is under mains pressure warranty is void in this instance Galvin Specialised recommends that the handpiece is periodically serviced by a qualified plumber IMPORTANT To seal the hose this unit uses Loctite 577 which is a thread sealant approved for use with potable water...

Страница 5: ...ranties express or implied Galvin Engineering Pty Ltd hereby specifically disclaims all other warranties express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Galvin Engineering Pty Ltd products are covered under our manufacturer s warranty available for download from www galvinengineering com au Galvin Engineering Pty Ltd ex...

Отзывы: