3.  Testing 

 

Once fitted, connect the water lines & turn on water. 

  Check for leaks and correct operation.

 

 

TROUBLESHOOTING

 

PROBLEM 

CAUSE 

RECTIFICATION 

Water is not flowing or 
inconsistent flow. 

Blocked flow restrictor / dirt in the 
cartridge / water supply not on. 

Remove flow regulator from outlet and 
remove debris. Install an inline strainer to 
stop further blockages.  Ensure water 
supply is turned on. 

Continous flow of 
water. 

Top assembly cartridge loose or 
internally obstructed or damaged. 

Remove cartridge, clean with water and re-
grease spindle if required. 

Rate of flow 
inadequate. 

The flow restrictor may not be 
satisfactory due to inadequate supply 
pressure. 

Remove flow restrictor and replace with a 
flow restrictor of different capacity to suit 
(available from Galvin Engineering). 

Button hard to activate. 

Mains pressure may be too high. 

Reduce mains pressure to below 500kPa. 

Water shuts off upon 
releasing the button. 

Small spring at the bottom of the 
cartridge piston dislodged. 

Relocate spring & regrease spindle if 
required.

 

 
 
 

 