TOOLS REQUIRED

 

  Power drill 

  Spanner or adjustable crescent

 

  Screw driver

 

 

PRE-INSTALLATION -

 MOUNTING DETAILS

 

 

If the mounting holes do not already exist, mark out and drill the holes in 
the bench/trough, as shown in rough-in dimensions. 

 

 

Note: Before installation, all lines must be flushed.   

We recommend that a line strainer be installed prior to drinking taps to eliminate 
any foreign material.  

 

 

INSTALLATION

 

IMPORTANT: Galvin  Specialised products must be installed  in  accordance with these  installation  instructions 
and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical 
supply  conditions  must  also  comply  to  the  applicable  national  and/or  state  standards.  Failing  to  comply  with 
these provisions shall void the product warranty and may affect the performance of the product. 

 

 

1. Disassemble 

 

Remove back nut and cup washer from the  
outlet assembly.

 

 

Remove the back nut from the piezo button.

 

2. Fit mouthguard outlet 

  Fit the mouthguard outlet into the trough. 

  Ensure the sealing rubber washers are placed 

underneath the mouthguard outlet body. 

  Secure underneath with the supplied cup washer and 

back nut. 

  Take care not to over-tighten. 