TM-BASCP

As supplied, this mixer delivers full flow hot and cold 
water. To use the anti-scald feature adjust the stop ring 
as follows:

1.  Remove indicator plug (3). Using 2.5mm allen key 

(4) loosen screw (2) and remove handle (1). Unscrew 
cap (5) taking care not to damage the chrome finish.

2.  Using a small screwdriver, carefully remove the red 

stop ring (7) and reposition it in an anti-clockwise 
direction as required so that the spline teeth in the 
stop ring (7) engage with the spilne teeth on the 
cartridge (8). As a guide, rotate the stop ring (7) by 1 
spline in an anti-clockwise direction. This will restrict 
the handle movement in the hot water direction by 8 
degrees of rotation. Push the stop ring (7) fully down.

3.  Check the hot water temperature with the handle 

in the fully open hot water position. If required 
adjust the stop ring (7) until a satisfactory hot water 
temperature is achieved. Ensure stop ring is fully 
pushed down.

4.  Replace  cap  (5), tighten by hand.  Fit handle  (1) 

taking care that it is pushed fully down. Tigthen grub 
screw (2) and replace handle plug (3).

Adjusting the Anti-scald Stop Ring 

(Fig 2) 

Replacing Aerator Insert

1.  Carefully remove aerator housing (17) from mixer 

body (9) taking care not to damage the decorative 
finish.

2.  Remove seal (19) and aerator insert (18) from aerator 

housing. Check that aerator housing is clean and 
clean any debris that is blocking the flow.

3.  Fit new aerator insert (18) into aerator housing (17) 

followed by seal (19) then screw assembly into mixer 
body (9) and tighten securely (to prevent removal by 
hand).