Version 2, 2 June 2017, 2 of 4
PRE-INSTALLATION
- Mounting Details
Hole Centres
Hole centres must be at 215mm ±0.5mm, this
is critical to ensure easy installation
Wall spuds must be 15BSP MI and protrude
from the finished wall by no more than 15mm
Note: In some situations a male thread connection
on the tap may be more suited. If so, please
contact us on 1300 514 074
INSTALLATION
IMPORTANT:
Galvin Specialised products must be installed in accordance with these installation
instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water
and/or electrical supply conditions must also comply to the applicable national and/or state standards.
Failing to comply with these provisions shall void the product warranty and may affect the performance of
the product.
1. Fit wall flange
Remove the maintenance tails from the
CliniLever
®
body and take the wall flanges out of
the packaging.
Slide the wall flanges over the maintenance
tails, ensuring supplied o-rings are in the rear
groove of the flange.
2. Fit maintenance tail
Fit the maintenance tail (with the wall flange) to
the wall spud and fasten with the supplied 12mm
allen key. We recommend using thread tape or
equivalent to ensure the connection does not
leak.
SERVICEABLE
INLINE FILTER
VALVE
ISOLATION
1/2" BSP FI
NOM
265
150
155
7 LPM
LAMINAR
FLOW
AERATOR
215