Version 2, 30 August 2018, 2 of 4 

 

PRE-INSTALLATION

 

MOUNTING DETAILS 

 

 

If the mounting holes do not already exist, mark out and drill the holes in the bench/trough, as shown 
in rough-in dimensions. 

 

Note:

 Supplied flexi hose length is 450mm long.  Maximum distance between outlet and push button 

adjustment is 420mm. 

 

 

INSTALLATION

 

INSTALLATION  COMPLIANCE:

  Galvin  Engineering  products  must  be  installed  in  accordance  with  these 

installation  instructions  and  in  accordance  with  AS/NZS  3500,  the  PCA  and  your  local  regulatory 
requirements.  Water  and/or  electrical  supply  conditions  must  also  comply  to  the  applicable  national  and/or 
state  standards.  Failing  to  comply  with  these  provisions shall  void  the  product  warranty and  may affect the 
performance of the product. 

 

IMPORTANT: 

Whilst our product designs take into account a broad range of installation types and surfaces, 

it  is  important  that  surfaces  which  fixtures  are  mounted  to  are  flat  and  free  from  defect.    This  is  especially 
important when installing product ranges that have been designed for correctional and health facilities, where 
special attention is required to minimise ligature points and areas for concealment of contraband. In addition 
to ensuring  the products are fitted securely and in accordance with the following instructions, consideration 
shall be given to the use  of non-pick mastics such as BASF Sonolastic “Ultra” to ensure a high quality and 
safe installation.

 

   22  

   4  

  15.0  

  15.0  

   22  

   4  

  420 MAX  

BENCH / TROUGH

 

FLOW DIRECTION

 22 

 70 

PUSH BUTTON ASSEMBLY

WATER HOSE 15F R/CONE

1/2"BSP

HEX W/ELBOW x 450mm LONG

1/2"BSP

1/2"BSP

ISOLATING/

REGULATING

BALL VALVE

BASIN OUTLET

 175 

 22 