TROUBLESHOOTING 

                            PROBLEM 

                               REPAIR CHECKLIST 

1.  No Flow. 

1.    Check the main shut-off valve. 

     2. Insufficient water flow  
 

2.  a. Verify minimum 210 kPa flowing 

   supply line pressure. 

          b. Probable clogging of flow control due  
              to inadequate line flushing. Unscrew 
              eye/face wash head and remove the 
              four screws to disassemble head. 
              Clean flow control and reassemble  
              Head. 
          c. Remove plug located on L 

– Strainer 

              

using a 9/16” wrench to access clean      

              filter screen. 

    3. Eye/face wash streams do not meet 
        desired eye level.  

3.  Possible blocked flow control, see above 

           solution. Possible non-leveled eye/face 
           wash assembly 

   4. Water does not drain properly. 

4.  Check the main waste line of your 

building to see if it does handle the 
capacity required for the entire drainage 
system. 