GalvinSafe

®

 Eye/Face Wash, Wall Mtd, Hand Act, 

Axion

®

 MSR Head, S/S Bowl w/ Body Spray (HAWS) 

PRODUCT CODE:  

Galvin Engineering: 190.42.11.90 

 

 

 

 

 

HAWS: 7778B-A

 

 

HAWS: 8901B

 

 

PRE 

– INSTALLATION: 7778B-A 

LOCATION OF UNIT: 

The Model 7778B-A Eye/Face Wash should be installed in close 

proximity to potential accident areas. It should be clearly identified, free from obstructions 
and easy to access. 

 

SUPPLY LINE: 

The minimum recommended line size 

is 1/2” BSPT with 210 – 600 kPa 

flowing pressure. Where sediment or mineral content is a problem, an inlet filter is 
recommended. 

 

PLUMBING CONNECTIONS: 

Inlet supply is female 1/2” BSPT. Waste outlet is male 1-

1/4

” BSPT. 

PRE 

– INSTALLATION: 8901B 

LOCATION OF UNIT: 

The Model 190.43.55.32 (8901B) Hose Spray should be installed 

in close proximity to potential accident areas. It should be clearly identified, free from 
obstructions and easy to access.  

 

SUPPLY LINE: 

The minimum recommended line size is 

1/2” BSPT with 210 – 600 kPa  

flowing pressure. Where sediment or mineral content is a problem, an inlet filter is 
recommended. A vacuum breaker is required to be used with this item. (Not supplied with 
the product or by Galvin Engineering) 

 

PLUMBING CONNECTIONS: 

Inlet supply is male 1/2” BSPT.  