INSTALLATION

 

INSTALLATION COMPLIANCE

: Galvin Specialised products must be installed in accordance with these 

installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. 
Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.  
Failing to comply with these provisions shall void the product warranty and may affect the performance of the 
product.

 

 

 

1.  Measure and cut support rod 

  Measure the distance between the wall mounting 

surface and the centre line of the drilled hole in 
the bench/trough (dimension “A”). 

  Take dimensions “A” and subtract 16mm. This is 

the required length of the support rod 

(Required 

support rod length = A-16mm). 

  Cut the support rod accordingly; ensure the 

threaded end is 

NOT

 cut off.

 

 

Note: Distance “A” must be no less than 70mm. 
The support rod length can be 70mm min. to 285mm 
max. (If it is more than 285mm, an extension support 
rod must be purchased)

 

2.  Fit wall bracket 

  Secure the wall bracket to the wall.

 

  Supplied fasteners may not be suitable for 

the mounting surface.  If this is the case, 
suitable fasteners will need to be sourced.

 

Note: The wall bracket must be mounted with three 
screws for stability and strength. This is critical 
and failure to do this may void the warranty.

 

 

 

3.  Fit support rod 

 

If pot filler kit (TF81HJP) has been purchased, it 
must be attached to the pre-rinse unit prior to 
fitting the support rod to the riser.  Refer to the 
installation instruction supplied with the pot 
filler.

 

 

Screw support rod into the riser hook and 
ensure it is not fully tightened. 

4.  Fit upper riser to lower riser 

  Remove protective cap from upper riser 

spindle.

 

  Fit the upper riser to the lower riser, ensure 

the sealing o-rings are inside the spindle.

 

  Tighten with new supplied grub screw

 

It is critical that the grub screw point 
locates accurately into hole recess of 
mating part. Failure to do so may result in 
damage and/or failure of the unit

.

 