© Galvin Engineering Pty Ltd
Product Installation Guidelines
Document No.: 001.00.10.17
Version 1, 4 November 2022, Page
3
of
4
3. Fit water temperature indicator
−
Once lever handle is secure, fit the water
temperature indicator.
−
Ensure the set is installed with hot and cold
in the correct location.
4
.
Testing
−
Once temperature indicator is fitted, check the
operation of the unit, and inspect for any
leaks.
TROUBLESHOOTING
PROBLEM
CAUSE
RECTIFICATION
Taps are dripping water
Jumper valves are worn or damaged
Replace jumper valve
Ceramic discs are worn or damaged
Remove and inspect SBA.
Remove debris and/or replace
SBA if damaged.
Tap seat is damaged
Refurbish tap seat using a
reseating tool.
Water is leaking from spindle
O-ring on jumper valve spindle is
damaged or worn
Replace o-ring
Water is not flowing from tap
Water is turned off
Turn water on
Aerator or flow regulator is blocked by
debris
Remove aerator and/or flow
regulator from tap and remove
debris. Install an inline strainer.
Spindle is difficult to turn
(jumper valve)
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Remove jumper valve, clean and
regrease. Replace o-ring.
Complete SBA may need to be
replaced.
Handle is loose
Screw has come loose
Tighten handle screw