background image

 

© Galvin Engineering Pty Ltd 

 

Product Installation Guidelines 

Document No.: 001.00.10.17 

Version 1, 4 November 2022, Page 

3

 of 

4

 

 

3.  Fit water temperature indicator 

 

Once  lever  handle  is  secure,  fit  the  water 
temperature indicator.

 

 

Ensure the set is installed with hot and cold 
in the correct location.

 

 

4

.

 Testing 

 

Once temperature indicator is fitted, check the 
operation  of  the  unit,  and  inspect  for  any 
leaks.

 

 

 

TROUBLESHOOTING 

PROBLEM 

CAUSE 

RECTIFICATION 

Taps are dripping water 

Jumper valves are worn or damaged 

Replace jumper valve 

Ceramic discs are worn or damaged 

Remove and inspect SBA. 
Remove debris and/or replace 
SBA if damaged. 

Tap seat is damaged 

Refurbish tap seat using a 
reseating tool. 

Water is leaking from spindle 

O-ring on jumper valve spindle is 
damaged or worn 

Replace o-ring 

Water is not flowing from tap 

Water is turned off 

Turn water on 

Aerator or flow regulator is blocked by 
debris 

Remove aerator and/or flow 
regulator from tap and remove 
debris. Install an inline strainer. 

Spindle is difficult to turn  
(jumper valve) 

Build up of scale on spindle, spindle 
worn or o-ring has been damaged 

Remove jumper valve, clean and 
regrease. Replace o-ring. 
Complete SBA may need to be 
replaced. 

Handle is loose 

Screw has come loose 

Tighten handle screw 

 
 

Отзывы: