INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and in
accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply
conditions must also comply to the applicable national and/or state standards. Failing to comply with these provisions
shall void the product warranty and may affect the performance of the product.
Note: (Illustrations are for representation of installation only and is not limited for use to these components)
1. Remove Handle
−
Prior to installation turn off the water supply
.
−
Remove the handle assembly. To prevent
damage, carefully pry off plastic indicator from
the handle. (Use a small flat bladed screwdriver
if necessary).
2. Replace spindle assembly
−
Unscrew the head part from the threaded sleeve
using a 17mm spanner.
−
Check seat inside tap body for pitting or damage.
Re-seat if necessary
3. Refit new head part
-
Refit new head part into tap body.
Note: do not tighten cartridge using the handle
as this will result in damage to the cartridge
4. Reassemble Handle
-
Refit adaptor and reassemble handle by reversing
step 1.
-
When installation is complete, slowly open water
supply and inspect for leaks.
New ceramic head
New head part