background image

Installation and Operating Manual / Warranty Card

Water heater

type 

SGW(S): Maxi / Maxi Plus / M

SGW(S) Maxi

SGW(S) Maxi Plus

SGW(S)M

  250 l
  300 l
  400 l
  500 l
  700 l
  1000 l

  300 l
  400 l
  500 l

  300 l
  400 l
  500 l

  Titanium anode (water heater is equipped with a magnesium anode as standard)

Please read the instructions carefully before beginning the installation and use of the product.

Cat. No./ Serial No. ..............................

Date of manufacture ...........................

QC

www.galmet.eu

Made in Poland

Содержание SGW(S) Maxi 250

Страница 1: ...W S M 250 l 300 l 400 l 500 l 700 l 1000 l 300 l 400 l 500 l 300 l 400 l 500 l Titanium anode water heater is equipped with a magnesium anode as standard Please read the instructions carefully before...

Страница 2: ...heaters 250 300 400 500 6 5 2 Scheme of the SGW S Maxi water heaters 250 300 400 500 7 5 3 Technical specification of the SGW S Maxi water heaters 700 1000 8 5 4 Scheme of the SGW S Maxi water heater...

Страница 3: ...by warranty 7 Eliminate contamination by using filters to extend the service life of the tank and ensure proper functioning of the relief valve 8 Iftanksoperateinaveryaggressiveenvironment e g inacow...

Страница 4: ...mally insulated If the system operation assumes the usable warm water heating priority using the three way valve we recommend following the installation instructions provided by the manufacturer of th...

Страница 5: ...CORREX and potentiometer plug must not be lengthened 2 A random change in polarity causes the acceleration of corrosion 3 It is recommended to use the socket 230V in a short distance from the tank 4 2...

Страница 6: ...39 Demand for heating water m3 h 3 3 3 3 Dimensions h1 Cold water inflow height mm 130 130 150 180 h2 CH water outflow height mm 215 215 235 265 h3 Sensor cover height mm 385 540 560 610 h4 Circulati...

Страница 7: ...eserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S Maxi Maxi Plus M 7 5 2 Scheme of the SGW S Maxi water heaters 250 300 400 500 d D L h6 h5 h4 h3 h2 h1 0 5 Technical s...

Страница 8: ...0 10 45 C kW 39 39 Demand for heating water m3 h 3 3 Dimensions h1 Cold water inflow height mm 215 245 h2 CH water outflow height mm 395 445 h3 Sensor cover height mm 755 745 h4 CH hot water inflow he...

Страница 9: ...ts reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S Maxi Maxi Plus M 9 5 4 Scheme of the SGW S Maxi water heaters 700 1000 d D L h6 h5 h4 h3 h2 h1 0 5 Technical spec...

Страница 10: ...m3 h 3 3 3 Dimensions h1 Cold water inflow height mm 130 160 180 h2 CH water outflow height mm 215 245 265 h3 Sensor cover height mm 335 425 410 h4 CH hot water inflow height mm 495 565 645 h5 CH wate...

Страница 11: ...ed Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S Maxi Maxi Plus M 11 5 6 Scheme of the SGW S Maxi Plus water heaters 300 400 500 d D h8 h7 h5 h3 h2 h1 0 h4 h6 L h9 5 Techn...

Страница 12: ...height mm 210 240 255 h3 Solar water outflow II height mm 290 325 355 h4 Solar sensor cover I height mm 390 475 525 h5 Sensor cover II height mm 490 625 655 h6 Solar water inflow II height mm 670 905...

Страница 13: ...Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S Maxi Maxi Plus M 13 5 8 Scheme of the SGW S M water heaters 300 400 500 d D h8 h7 h5 h3 h2 h1 0 h4 h6 L h9 h10 h11 h12 5 Tec...

Страница 14: ...SGW S M 300 SGW S M 300 Intended use The water heaters are intended for heating and storage of the DHW The wall thickness of the jackets and the bottoms as well as the material the exchangers were mad...

Страница 15: ...ency class B B C B C C 4 EN Standing loss W 63 65 95 82 106 131 5 EN Storage volume L 236 284 376 471 657 973 7 2 SGW S Maxi Plus 1 EN Supplier s name or trade mark Galmet 2 EN Supplier s model identi...

Страница 16: ...mbleddirectlyinfrontoftheheateronthepipesupplyingitwithcoldwater Onlyvalvesacceptablebyadequateorgansshould beused adjustedtostoragewaterheaters Safetyvalveshouldbeusedaccordingtotheoperatingmanualfor...

Страница 17: ...Themethodforrepairshallbespecifiedbythemanufacturer 21 Multiple repairs will not include the following heater adjustment replacement of magnesium anode replacement of gaskets nor any element wearing d...

Страница 18: ...Notes...

Страница 19: ...f repair Service s seal Service s seal Service s seal Service s seal Owner s name and address Owner s name and address Owner s name and address Owner s name and address Owner s signature Owner s signa...

Страница 20: ...Installation confirmation Type Factory no Date of sale Seller s stamp and signature Warranty coupon 1 Warranty coupon 2 Warranty coupon 3 Warranty coupon 4 Type Type Type Type Factory no Factory no Fa...

Отзывы: