3. Troubleshooting / 4. Technical specification

3. Troubleshooting

PROBLEM

CAUSE

METHOD OF ELIMINATION

The safety valve does not open
{even doing a blow through).

Safety valve seized.

Clean or replace the valve.

Safety valve leaks.

Touching surfaces of safety valve dirty or 
defective.

Clean or scrub the touching surfaces of the safety valve.

Excessive water pressure in the network.

Instal a flow control device.

Water from the water heater is dirty.

A large amount of sediment in the tank.

Clean the tank of sediment.

Worn out magnesium anode

Replace the magnesium anode - not covered by the warranty.

Warning!

1.  At least once every 18 months replace the magnesium anode (keep the receipt for the magnesium anode). Regular replacement of the magnesium 

anode is a requirement for maintaining a warranty on the tank (for an enamelled tank).

2.  It is not allowed to install the water heater without a properly functioning safety valve.
3.  The safety valve must be installed directly in front of the cold water pipe leading to the water heater. Only valves approved by the Technical Supervision 

Office, designed for capacitive water heaters, can be used – ones with a return valve. The safety valve allows water to flow out of the heater, if an 
excessive increase in pressure in the heater occurs – opening pressure of 0,67 MPa.

4.  No additional device can be installed between the safety valve and the water heater (e.g. shut off valve, water valve, etc.).
5.  The repair method is specified by the manufacturer.
6.  In the event of product defects importer. Free repairs of damage, for which the manufacturer is liable, will be remedied within 14 days from the date 

of notification. THE WATER HEATER MUST NOT BE DISASSEMBLED. The receipt for the purchase of the water heater must be kept for after sales service 
purposes. The number of repairs does not include gasket replacements, magnesium anode replacements etc.

7.  A properly filled out, complete and in no way corrected warranty card is the basis for having repairs done under warranty (it must be kept throughout 

the warranty period).

8.  Cases not covered by the above conditions are subject to the provisions of the Polish Civil Code.
9.  Connections with the heaters must not be made of plastic pipes not designed to work at a temperature of 95°C and at a pressure of 1,0 MPa.
10.  Water heaters must be installed in such a way as to ensure easy access (e.g. for maintenance, repair or replacement).
11.  The manufacturer is not liable for any inconvenience or expense caused by the dismantling of additional housing elements.
1.  In case water becomes odorous or darkly coloured, this is caused by the formation of hydrogen sulfide by sulfate reducing bacteria that live in oxygen 

poor water. If cleaning the water heater, replacing the magnesium anode and setting the temperature above 60°C do not improve the situation, we 
recommend the use of a titanium anode connected separately to the power supply.

4. Technical specification 

Specification

unit

SG(S) Fusion 100

storage capacity 

*

l

104

Tank's maximum working temperature

°C

95

Tank's maximum working pressure

MPa

1

Magnesium anode - top cover 5/4" plug

mm

25x390

Height

mm

900

Internal diameter

mm

500

External diameter

mm

600

Net weight

kg

54

*

 According to the (EU) 812/2013, 814/2013.

Содержание SG Fusion 100

Страница 1: ...arranty Card Layered tank SG S Fusion 100 for dual function gas boilers Cat No Serial No Date of manufacture QC Please read the instructions carefully before beginning the installation and use of the product www galmet eu Made in Poland ...

Страница 2: ...e 3 1 1 Device description 3 1 2 Technical characteristics 3 1 3 Scheme 3 1 4 Remember 4 2 Installation 5 3 Troubleshooting 6 4 Technical specification 6 5 Titanium maintenance free active anode 7 5 1 Pros of the titanium anode 7 5 2 Troubleshooting 7 6 Product fiche 7 7 Declaration of Conformity 8 Table of Contents ...

Страница 3: ...r resultinginalargeamountofheatedwaterinashorttime Thankstoitslayeredwaterdistribution smallwaterconsumptiondoesnotstart the boiler too often This prolongs its life and allows the user to save gas 1 2 Technical characteristics The main part of the device is the tank in which the water is heated The tank is made from a sheet of steel which is then enamelled with a ceramic enamel on the inside part ...

Страница 4: ...safety valve do not block the escape hole of the safety valve If water leaks continuously from the safety valve it means that the pressure in the water pipe installation is too high or the safety valve is inefficient The outlet carrying out of the valve should be directed down Below the valve it is advisable to put a funnel carrying the water out You can also put on the outlet a pipe carrying the ...

Страница 5: ...he outlet of the safety valve must be open all the time connected with a normal atmosphere The tank acts as a buffer loaded from the top with warm water which does not mix with the cold water occupying the bottom section of the tank This solution greatly enhances the comfort of using a dual function boiler resulting in a large amount of heated water in a short time A 3 stage circulation pump stand...

Страница 6: ...he event of product defects importer Free repairs of damage for which the manufacturer is liable will be remedied within 14 days from the date of notification THE WATER HEATER MUST NOT BE DISASSEMBLED The receipt for the purchase of the water heater must be kept for after sales service purposes The number of repairs does not include gasket replacements magnesium anode replacements etc 7 A properly...

Страница 7: ... anode The anode is contacted with the mass of the tank Fill the tank with water Put the cables at the anode Check and clean the rust all connections Properly isolate the anode from the tank It is NECESSARY to use a dielectric connectors made out of a plastic material electrically nonconductive between the hot and cold water connections and the installation s connections in order to avoid iron cop...

Страница 8: ...pplies to is compliant with the following directives Pressure Equipment Directive PED 2014 68 UE The water heaters are intended for heating and storage of the DHW The wall thickness of the jackets and the bottoms as well as the material the exchangers were made of are listed below Type Diameter Ø Bottoms Material Jackets Material Material thickness Material thickness SG S 100 500 3 0 S235JR 2 5 S2...

Страница 9: ... All rights reserved Galmet Sp z o o Sp K Installation and Operating Manual SG S Fusion 9 Notes ...

Страница 10: ...Installation and Operating Manual SG S Fusion All rights reserved Galmet Sp z o o Sp K 10 Notes ...

Страница 11: ...l of the service Seal of the service Seal of the service Seal of the service Name address of the owner Name address of the owner Name address of the owner Name address of the owner Owner s signature Owner s signature Owner s signature Owner s signature No Date of receiving Description of the repair Date of worksmanship Serviceman s signature ...

Страница 12: ... 4 Type Type Type Type Factory No Factory No Factory No Factory No Date of sale Date of sale Date of sale Date of sale Seller s seal and signature Seller s seal and signature Seller s seal and signature Seller s seal and signature Magnesium anode replacement confirmation paid service Date and signature of an authorized person Date and signature of an authorized person Date and signature of an auth...

Отзывы: