1. General information
1.3. Technical-operational parameters of the Galaxia KWE boiler
Parameters
Unit
Galaxia KWE
Rated output
kW
12,0
17,0
22,0
Output range
kW
4,0 ÷ 12,0
5,0 ÷ 17,0
6,6 ÷22,0
Boiler class acc. to EN 303-5:2012 standard
-
5
Boiler heating surface area
m
2
-
-
3,24
Fuel
-
SILESIAN eco-pea coal granulation 8 ÷20
Fuel class
-
a1 (according to the EN 303-5 norm)
Fuel bin capacity
l
150
240
Real fuel stream (at maximal capacity)
kg/h
-
-
3,022
Combustion stability for the rated output
h
-
-
60
Thermal effectiveness
%
-
-
94
Required chimney draught
mBar
-
-
0,20
Minimal chimney height
m
6
Minimal chimney cut section area
mm
Ø 160
Flue gas temperature for the rated output
°C
-
-
71
Flue gas temperature for the minimal output
°C
-
-
61
Flue gas mass stream for the rated output
kg/s
-
-
0,0083
Flue gas mass stream for the minimal output
kg/s
-
-
0,0035
Flow resistance
mbar
-
-
147
Operation temperature range
°C
55÷85
Maximal temperature on supply
°C
85
Minimal temperature of return
°C
55
Permissible operation pressure
bar
2,2
Boiler water capacity
l
-
-
90
Boiler mass including the burner, feeder and bin
kg
-
-
533
Outer diameter of flue
mm
Ø 160
Supply/return tube diameter
”
6/4
Discharge tube diameter
”
½
Boiler height
mm
-
-
1660
Boiler width
mm
-
1165
Boiler depth
mm
-
1320
Flue distance to the floor
mm
-
-
1397
Maximum power consumption
W
354
Stand-by power consumption
W
4
Electric connection/protection
-
230V~/50 Hz, 6,3A/250V~
Protection degree
IP
40
Noise emission (EN ISO 12100:2010)
dB
< 66
Operation with a blowing fan
-
tak