- 3 -
OPERATION MANUAL AND WARRANTY CARD
"Galmet Sp. z o.o.”
The pump installation and start-up can be carried out only by
manufacturer's service team or a fitter duly authorized after
attending a manufacturer's training. Otherwise the warranty
covering the device will not be granted.
Please read and understand this operation manual. Failure to follow the
instructions provided in this manual can result in voiding the warranty or in permanent
damage to the device.
This equipment is not intended for use by persons (including children) with
limited physical, sensual or mental abilities and persons inexperienced or not knowing
the equipment. It is allowed only when it is carried out under supervision or by
following the equipment operating instructions provided by persons responsible for
their safety.
The device should be installed by following good construction practices and in
accordance with locally valid regulations and standards. The device is intended for
indoor installation.
1. Use and operation
The EASY AIR BASIC 2 GT heat pump is an air-to-water heat pump making it
possible to provide domestic hot water maximum for a 6-person family. The maximum
temperature of the domestic hot water generated by the heat pump is 50°C. However,
for energy-saving reasons it is recommended not to set the temperature of domestic hot
water above 45 °C, as it will result in raising the costs of using the heat pump and will
cause premature wear of the heat pump unit components.
Water temperature exceeding 50ºC can cause serious burns. Special
attention should be paid to avoid burns in children, the disabled or elderly
people.
2. Device description
The Easy Air Basic 2 GT heat pump contains one heat generator and an electric
heater used to collect heat in the accumulator tank and heat it to a preset temperature.
The pump incorporates a coil providing an opportunity to connect an external heat
source, e.g. a central heating boiler. The heat pump receives heat from the air
surrounding it and uses it to heat up the water in the accumulator tank. The heat pump
can be also connected to air ducts, but their diameter cannot be lower than 160 mm and
their overall length cannot exceed 10 m. During operation the heat pump absorbs
moisture from the room air and therefore the condensate generation is a normal
phenomenon; the condensate drain pipe is located under the device and it should be
directed to the sewage system.