Gallien-Krueger Microbass MB150E/112 Скачать руководство пользователя страница 3

3

MicroBass-III Series

Safety Information

Please read all enclosed safety precautions, before 
connecting or operating this product.

Verify Line Voltage and Amperage Before Use:

Your new MicroBass Series amplifier has been 
factory configured for use with:

120 Volt/60Hz 15 A circuit for  USA/Canada.
230 Volt/50Hz 10 A  circuit for UK/Australia.
240 Volt/50Hz 10 A  circuit for Europe.
100 Volt/50Hz 15 A  circuit for Japan.
220 Volt/50Hz 10 A  circuit for Korea.

Connecting the amplifier to a line with specifications 
other  than indicated above can create a safety or 
fire hazard and may damage the amplifier.  If you 
have any questions about the voltage requirements 
for your specific model, or about the line voltage 
in your area, contact your dealer before plugging 
the unit into a wall outlet.

Verify AC Circuit Capacity Before Use:

The high power output of your amplifier may require 
heavy current draw  under full-load conditions.  To 
insure proper performance and avoid potential safety 
hazards, we recommend connection to line circuits 
with amperage specified “as above”.  Connecting 
multiple amplifiers to the same circuit, or  connect-
ing the amplifier to the same circuit used by other 
heavy-power devices, such as high-wattage lights, 
may cause circuit breakers to trip.  It is always a 
good idea to avoid using any audio equipment on 
the same AC circuit as equipment with motors, such 
as air conditioners or refrigerators.  This will lessen 
the possibility of power variation and electrical 
start-up noise affecting your sound.

AC Power Cord:

To avoid  safety hazards, use only the power cord 
supplied with your unit.  If a replacement cord is 
needed, make certain that to use a standard IEC 
compliant cord.  Damaged power cords should be 
replaced immediately. 

Connecting to AC Power:

When setting up, make certain that the AC plug 
is easily accessible.  If mounting in a rack, ensure 
that the AC mains can be easily disconnected by 
a plug or by an all-pole disconnect switch on or 
near the rack.

Disconnect  When Not In Use:

If you do not intend to use the amplifier for a 
considerable length of time, disconnect the plug 
from the AC outlet.  Just switching the unit off 
does not  mean that it is fully disconnected from 
the AC Mains. To isolate the unit from the  AC 
mains, you must disconnect the power cord from 
the unit and the AC outlet.  When disconnecting 
the power cord always pull from the plug, never 
pull from the cord.  

 

Do Not Open the Amplifier Enclosure:

There are no user-serviceable components inside 
this product.  Opening the amplifier enclosure 
may present a shock  hazard, and modification 
to the product will void your warranty.  If liquid 
enters the unit, or any metal object such as a paper 
clip, wire, or staple accidentally falls inside the 
enclosure, disconnect the unit from the AC power 
source immediately and consult an authorized 
service station.

Unpacking:

The  carton and packing materials used in shipping 
your new amplifier were specifically designed to 
cushion it from the shocks and vibration that occur 
during transport.  We suggest that you save the carton 
and packing materials for use in shipping, in the 
event you move, or the amplifier  needs repair.

Safety Information

Содержание Microbass MB150E/112

Страница 1: ...Series III OWNERS MANUAL MB150E MB150S MB150E 112 MB150S 112...

Страница 2: ...d Advice 9 Tech Talk 10 Specifications 12 Warning Our amplifiers are capable of producing high sound pressure levels Continued exposure to high SPL s can cause damage to your hearing Always set the vo...

Страница 3: ...rt up noise affecting your sound AC Power Cord To avoid safety hazards use only the power cord supplied with your unit If a replacement cord is needed make certain that to use a standard IEC compliant...

Страница 4: ...lugged amplifiers up stairways and into car trunks always wondering why these things had to be so heavy bulky and hard to handle As I am the principal innovator at GK our prod ucts reflect my attitude...

Страница 5: ...the unit No other maintenance should be necessary Quick Start Plug It In Set the power switch to Off and connect the sup plied power cord from the amplifier s AC recep tacle to an AC power outlet of p...

Страница 6: ...ge using GK s exclusive Valve Effect which adds growl as it is turned up May be engaged with the RF2 Footswitch 16 Stereo Chorus LED MBE Only LED is lit when the Stereo Chorus is engaged 17 Chorus On...

Страница 7: ...t is on a different ground system 10 Direct Out Mode Switch MBE Only When Mode 1 is selected XLR Right is Mono Post and XLR Left is Mono Pre When Mode 2 is selected the Direct Outs are Post Left Right...

Страница 8: ...8 MicroBass III Series Sample Settings Pop Fuzz Tone Limiter On Reggae Limiter On Acoustic Upright Walking Bass Slap Limiter On...

Страница 9: ...Control The Boost Control adjusts the Valve Effect See Tech Talk for more info Turning up the Boost will add a little growl to your tone This is an unmistakable highly sought after GK trademark sound...

Страница 10: ...add to one another without creating unmusical peaks or valleys The result is an equal izer that is easy to use and sounds natural at any setting Voicing Filters Voicing filters are used to completely...

Страница 11: ...higher signal level drops back down By using a Class H power supply it eliminates the need for a fan Convection cooling is used instead for completely silent operation in the studio or on stage This w...

Страница 12: ...V 50Hz 325W full power 54W average power MicroBass III Series Owner s Manual Part 160 0210 A Block Diagram MicroBass Series Specifications Output Power 100W 8 Ohms 150W 4 Ohms Input Section Maximum In...