Gallien-Krueger Fusion 550 Скачать руководство пользователя страница 11

10 

11

Fusion 550 Bass Amplifier

Horn Bi-Amp Operation:    

Bass players have al-

ways liked the growl they get from a slightly over 

driven GK power amp.  The problem is that growl 

sounds  great  through  woofers  but  will  destroy  the 

horn (tweeter).  In a typical full range system, there is 

no way to get that growl while keeping the defini-

tion that the horn provides.  In GK’s Horn Bi-Amp 

system, an active (electronic) crossover allows a full 

range signal through to the main (woofer) amplifier, 

while only the high frequency portion of the signal 

(5kHz and above) is allowed through to the 50 watt 

Horn  amplifier.   There  are  three  primary  benefits 

to this system over a traditional full range system.  

Significantly reduces the risk of blowing out 

the horn’s diaphragm.

More  accurate  and  natural  sounding  signal 

reproduction.

Allows you to add as much growl to the woofer 

signal  as  you  want  while  keeping  the  horn 

crystal clear.     

Headroom:

       The  Fusion  550  amplifier  uses  a 

high gain, low noise valve input stage with such 

a large dynamic range (60v p-p) that even basses 

with active electronics may not need to use the in-

put pad.  The benefit to you is a cleaner signal with 

less hiss and much less overall noise.

Efficiency:

    The power supply of the Fusion 550 

uses  a  unique  design  which  switches  between  a 

low  voltage  rail  for  normal  output  levels  and  a 

high voltage rail to accommodate peak levels. This 

much  more  efficient  approach  allows  us  to  build 

amplifiers  with  significantly  greater  output  level 

and significantly less heat and weight.  We’ve also 

added a temperature sensitive cooling system with 

a variable speed fan.  Under normal conditions, the 

fan will be off or spinning at a low speed.  As the 

amplifier  works  harder,  the  fan  speed  increases, 

maintaining a safe temperature level.

 

Intelligent  Protection  Circuitry:

        Gallien-

Krueger  amplifiers  use  intelligent  protection 

circuitry  which  constantly  monitors  for  any  un-

safe operating conditions such as short circuits or 

improperly wired speaker cables.  If an unsafe condi-

tion is detected, the output signal is immediately mut-

ed and the power light changes from blue to red.  

The amplifier will remain muted until the fault is 

removed.  If the protection circuit activates while 

playing, turn the amplifier off and check that you 

have  not  exceeded  the  maximum  recommended 

impedance load described in this manual.

Direct Out:

    The Fusion 550 uses a transformer 

balanced DI (Direct Inject) output for connecting to 

PA and recording consoles.This output is calibrated 

for 1.0V (0 dBV) and can be adjusted via the Level 

control to match the input sensitivity of the mixing 

console.  A Ground (Gnd) Lift switch is included to 

remove hum and buzz when used with equipment  

connected to a different ground system.   The Post 

EQ button allows you to set the Direct Out signal 

to either ‘Pre’ or ‘Post’ EQ.

    

Pre EQ:

    With the Pre/Post EQ button out (Pre), 

the  Direct  Out  signal  is  fed  straight  from  the 

input stage and is only effected by the -10dB Pad, 

Tuning Mute, and the Direct Out Level control.  

Adjustments to the voicing filters or EQ section 

will have no effect on the Direct Out signal.  

Post EQ:

    With the Pre/Post EQ button in (Post),  

any changes you make in the Gain, Shaping fil-

ters, EQ section and Effects Loop (if used) will 

affect the Direct Out signal going to the mixing 

console.

A Final Word:

    You should now have a thorough 

understanding  of  how  your  new  GK  amplifier 

works and the advantages it offers in helping to 

get ‘YOUR’ sound.  If you have any questions or 

comments, please visit our web site at www.gallien-

krueger.com or send us an e-mail to info@gallien.

com.  We wish you the best of times on your musical 
journey wherever it may lead you.  

Tech T

alk

Содержание Fusion 550

Страница 1: ...Fusion 550 Owner s Manual ...

Страница 2: ...ler or GK as soon as possible Gallien Krueger Inc 2234 Industrial Drive Stockton CA 95206 phone 209 234 7300 fax 209 234 8420 Internet www gallien krueger com Email info gallien com Always Listening I have never seen the point in doing things the way others have done them I also have not been very interested in following the latest fad I m a Stanford educated engineer who worked my way through sch...

Страница 3: ...ING CAUTION ATTENTION TO PREVENT ELECTRIC SHOCK MATCH WIDE BLADE OF PLUG TO WIDE SLOT FULLY INSERTED POUR EVITER LES CHOCS ELECTRIQUES INRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRE SPONDANTE DE LA PRISE ET POUSSER JUSQU AU FOND CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO The lightning flash with arrow head s...

Страница 4: ... Make certain that the AC outlet is properly grounded as well Do not use an adapter plug with this product Do Not Open the Amplifier Enclosure There are no user serviceable parts inside this product Opening the amplifier enclosure may present a shock hazard Modification to the product will void your warranty If liquid enters the unit or any metal object such as a paper clip accidentally falls insi...

Страница 5: ...n Bi Amp compatible speaker cabinet set it to Bi Amp using the switch on the back of the cabinet See Page 8 for more details on GK s Horn Bi Amp System Initial Front Panel Control Settings Set all ac tive equalizer controls and contour to 12 o clock and the bright and deep switches off Set the Gain and Master Volumes to 0 Connect Your Bass Using an instrument shielded cable connect your bass to th...

Страница 6: ...ich boosts and cuts the high frequencies 10 High Mid Active bandpass type control which boosts and cuts at about 1kHz 11 Low Mid Active bandpass type control which boosts and cuts at about 250Hz 12 Bass Active shelving type control which boosts and cuts the low frequencies 13 Horn Bi Amp Sets the ratio between the horn output and the master output 14 Master Master volume control 15 Power LED Power...

Страница 7: ...n a different ground system 8 Balanced Direct Out A transformer balanced low impedance output to run directly to the PAsystem via a 3 pin XLR cable 9 Pre Post EQ Takes the Direct Out signal from before or after the EQ section 10 Direct Out Level Controls the output level of the Direct Out signal 11 Speakon Outputs High current twist lock Speakon output connectors Pins 1 and 1 send a fullrange sign...

Страница 8: ...to Full range In this mode the cabinet s internal passive crossover is used to split the signal between the woofer and horn Use the Woofer Main knob on the front of the amplifier to control your output level The Horn knob is not used Note To avoid the risk of damage to the amplifier do not use a four conductor Speakon cable with non GK cabinets Instead use a two conductor Speakon or speaker cable ...

Страница 9: ...BASS CHANNEL C H 2 O F F PA S S I V E CONTOUR FREQUENCY 800 Hz 500 Hz O N O F F O N A C T I V E C H 1 GAIN O F F M U T E HORN BI AMP MASTER O N 12 O clock 9 12 O clock 12 3 O clock 12 O clock 9 12 O clock Off Off 800Hz Off Off 12 3 O clock 9 O clock 9 12 O clock Off On 800Hz 12 O clock 9 O clock 12 O clock 12 3 O clock Sample Settings Your GK amplifier is versatile in its sound and tone Below are ...

Страница 10: ...y in signal reproduction The treble is a shelving type control that boosts the high frequencies evenly Respectively the bass is a shelving control that evenly boosts the low frequencies The high mid and low mid are peak bandpass type controls with wide Q bandwidth patterns which are much more musical sounding Each of the four bands are connected in series meaning the output of the first band is fe...

Страница 11: ...ntaining a safe temperature level Intelligent Protection Circuitry Gallien Krueger amplifiers use intelligent protection circuitry which constantly monitors for any un safe operating conditions such as short circuits or improperly wired speaker cables If an unsafe condi tion is detected the output signal is immediately mut ed and the power light changes from blue to red The amplifier will remain m...

Страница 12: ...stant voltage crossover at 5kHz Noise 90dB A weighted Cooling Variable Speed Fan Protection Dimensions 5 25H x 19W x 10D Weight 27 5lbs Consumption 994W full 230W average Fuse 100V 120V T 10 A 220V 240V T 5 A Mains Voltage USA Canada 120 Volt 60Hz UK Australia 240 Volt 50Hz Europe 230 Volt 50Hz Japan 100 Volt 50Hz Korea 220 Volt 50Hz Mains Connect Standard IEC Receptacle Fullshortcircuit thermal R...

Отзывы: