Galletti WH SERIES Скачать руководство пользователя страница 7

7

SY66000120 - 03

All copying, even partial, of this manual is strictly forbidden

WH

Flap

Fan

1

2 3 4

5

6 7

JP1

SOCKET

F-cap

neutral

line

MV

aux2-2

room

freeze

switch

connector reveiver

low

med

high

connector

flap

F-cap

F-cap

aux1-2

aux1-1

freeze sensor

room sensor

Power supply

230V - 50Hz

cool

heat

sw2

R2 R1

sw1

on/off

rec mod

led1

system

led2

MV

C1

R3

Terminal board

F-cap

Motorized

 valve

-No jumper for without  motorized valve unit.

-With jumper for  motorized valve unit.

9

WIRING DIAGRAMS

LEGEND:

JP1:

NO JUMPER FOR UNIT WITHOUT  MOTORIZED VALVE

JP1:

JUMPER FOR UNIT  WITH MOTORIZED VALVE

REC MOD

(RECEIVER)

WH 10

Содержание WH SERIES

Страница 1: ...GB High wall fan coil units TECHNICAL MANUAL HIGH WALL FAN COIL UNITS ...

Страница 2: ...ater inside the heat exchanger that regulates the heating function according to the temperature of the water from 38 C to 75 C The auto restart function makes it possible to automatically restore unit management after blackouts Infra red remote control that when combinedwiththemicroprocessorcontrol allows simple versatile management of the fan coil temperature setting manual or automatic fan speed...

Страница 3: ... 30 C The internal fan speed can be set on Min Med Max and Auto The motor driven valve will be activated deactivated after a delay time of 30 sec If the water temperature is equal to or lower than 2 C the motor driven valve is deactivated and the internal fan continues working at the set speed TIMER The switch off timer can be set only when the system is ON The switch on timer can be set only when...

Страница 4: ...6 5 1940 1940 334 5 Tbs1 Tbu1 UR1 Tw1 Tw2 Vr PFT PFS Qw pw PFT PFS Qw pw PFT PFS Qw pw PFT PFS Qw pw W W l h kPa W W l h kPa W W l h kPa W W l h kPa 3 2590 1850 444 19 2270 1720 389 15 1900 1580 327 11 1540 1540 264 8 2 2320 1660 398 16 2020 1540 347 13 1680 1410 288 9 1370 1370 235 6 1 2190 1570 376 15 1900 1450 327 11 1560 1320 268 8 1280 1280 220 6 3 3670 2670 630 18 3050 2410 524 13 2500 2500 ...

Страница 5: ...9 12 7820 685 18 2 3490 607 16 5500 480 10 7090 622 15 1 3220 560 14 5070 443 9 6550 575 13 3 4920 856 20 7720 674 12 9960 873 19 2 4290 746 16 6730 588 10 8670 760 15 1 3960 688 14 6220 543 8 7990 701 13 Tbs1 Tw1 Tw2 Vr PT Qw pw PT Qw pw PT Qw pw W l h kPa W l h kPa W l h kPa 3 2390 415 13 3870 338 9 5080 446 14 2 2150 374 11 3490 305 7 4590 402 12 1 2040 355 10 3310 289 7 4350 382 11 3 3480 605 ...

Страница 6: ...SIONS 50 higher than eye level 80 floor ceiling 100 INSTALLATION CLEARANCE REQUIREMENTS Rear panel with water valve optionals 42 C A B D WH A B C D 10 870 183 225 276 20 1020 185 227 320 30 1160 213 255 330 590 110 170 870 190 60 276 770 160 90 1020 80 295 320 BACK VIEW 870 160 90 1160 90 305 330 ...

Страница 7: ...ctor flap F cap F cap aux1 2 aux1 1 freeze sensor room sensor Power supply 230V 50Hz cool heat sw2 R2 R1 sw1 on off rec mod led1 system led2 MV C1 R3 Terminal board F cap Motorized valve No jumper for without motorized valve unit With jumper for motorized valve unit 9 WIRING DIAGRAMS LEGEND JP1 NO JUMPER FOR UNIT WITHOUT MOTORIZED VALVE JP1 JUMPER FOR UNIT WITH MOTORIZED VALVE REC MOD RECEIVER WH ...

Страница 8: ... freeze switch connector reveiver low med high connector flap F cap F cap aux1 2 aux1 1 freeze sensor room sensor Power supply 230V 50Hz Motorized valve cool heat sw2 R2 R1 sw1 on off rec mod led1 system led2 MV C1 R3 Terminal board F cap Flap 2 No jumper for without motorized valve unit With jumper for motorized valve unit WH 20 30 9 WIRING DIAGRAMS ...

Отзывы: