background image

3E2362

 

Weigh

 

Scale

 

W310

 

v2

 

User

 

Manual

 

 

 

 

Page

 

29

 

 

Printing

 

A

 

Weigh

 

Scale

 

printer

 

can

 

be

 

attached

 

to

 

the

 

Weigh

 

Scale

 

W310

 

v2.

 

If

 

the

 

Weigh

 

Scale

 

printer

 

is

 

connected

 

during

 

a

 

weighing

 

session,

 

you

 

can

 

configure

 

the

 

Weigh

 

Scale

 

to

 

print

 

each

 

animal's

 

weight

 

automatically.

 

You

 

can

 

also

 

print

 

the

 

statistics

 

at

 

any

 

time

 

during

 

or

 

after

 

the

 

session.

 

The

 

Weigh

 

Scale

 

printer

 

has

 

its

 

own

 

internal

 

rechargeable

 

battery.

 

The

 

battery

 

can

 

be

 

recharged

 

using

 

the

 

battery

 

charger

 

supplied

 

with

 

the

 

printer.

 

Note

:

 

You

 

can

 

only

 

use

 

a

 

Weigh

 

Scale

 

printer

 

with

 

the

 

Weigh

 

Scale

 

W310

 

v2

 

scale.

 

 

Printing

 

weights

 

during

 

a

 

weighing

 

session

 

To

 

print

 

each

 

weight

 

during

 

a

 

weighing

 

session,

 

follow

 

these

 

steps.

  

1.

 

Connect

 

the

 

printer

 

cable

 

to

 

the

 

port

 

on

 

the

 

Weigh

 

Scale.

  

2.

 

Turn

 

the

 

mode

 

select

 

switch

 

to

 

S

 

to

 

display

 

the

 

SET

 

UP

 

menu.

  

3.

 

Select

 

COMMUNICATIONS

.

 

4.

 

Ensure

 

the

 

port

 

is

 

set

 

to

 

Printer

.

  

5.

 

Press

 

 

to

 

return

 

to

 

the

 

SET

 

UP

 

menu.

  

6.

 

Select

 

USER

 

OPTION

 

and

 

set

 

Live

 

Printing

 

to

 

ON.

 

7.

 

Press

 

 

to

 

return

 

to

 

the

 

SET

 

UP

 

menu.

  

8.

 

Select

 

the

 

required

 

weighing

 

mode

 

by

 

turning

 

the

 

mode

 

select

 

switch

 

to

 

A

 

(Automatic),

 

M

 

(Manual)

 

or

 

F

 

(Fine).

 

9.

 

Each

 

time

 

the

 

Weigh

 

Scale

 

captures

 

a

 

weight

 

it

 

will

 

be

 

printed.

 

If

 

Drafting

 

is

 

turned

 

on,

 

the

 

drafting

 

category

 

(H

high

 

or

 

L

low)

 

will

 

be

 

printed

 

beside

 

each

 

weight.

 

 

Содержание W310 v2

Страница 1: ...Instructions WEIGH SCALE W310 v2...

Страница 2: ...ry effort has been made to ensure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or actions they...

Страница 3: ...istics 20 Weight statistics 20 Deleting a weight from the statistics 21 Clearing the statistics 24 The weighing session 25 Weighing animals automatic or manual modes 25 Weighing static loads fine mode...

Страница 4: ......

Страница 5: ...for quality equipment that withstands tough agricultural conditions The Gallagher Weigh Scale range of weighing systems is simple tough innovative and reliable All of the Weigh Scales in the Gallaghe...

Страница 6: ...r care and maintenance can extend its life Listed below are guidelines for keeping the Weigh Scale in good condition Don t submerge the Weigh Scale in any liquid Store the Weigh Scale in a cool dry pl...

Страница 7: ...racket on a round post use the inner holes Don t mount the Weigh Scale bracket on the weighing crate or chute Installing the loadbars To install the loadbars follow these steps 1 Bolt the platform to...

Страница 8: ...a table top or mounted on the Weigh Scale bracket supplied Position the Weigh Scale clear of the platform to ensure it does not interfere with the flow of animals during the weighing cycle within eas...

Страница 9: ...y on its own will power the Weigh Scale continuously for a minimum of eight hours Charging the battery The battery in the Weigh Scale can be recharged using either a battery charger or an external 12...

Страница 10: ...ys in the bottom left corner of the Weigh Scale s upper screen It is important to note that the battery icon will only ever show the actual amount of charge left in the battery when the Weigh Scale is...

Страница 11: ...E2362 Weigh Scale W310 v2 User Manual Page 7 Low voltage shutdown When the battery charge drops to a critical level the Weigh Scale will shut down At this stage it is necessary to recharge the battery...

Страница 12: ...wer of the two Weigh Scale screens The explanatory information will display only for a few seconds after it disappears the screen displays information relevant to the selected option This position tur...

Страница 13: ...briefly appears Manual weighing is covered under Weighing static loads fine mode p 27 S This position accesses the setup options After the mode select switch is first turned to S the following informa...

Страница 14: ...3 COMMUNICATIONS sets up a connection to a device plugged into the Weigh Scale s communications port 4 SELECT COUNTRY for a specific country sets a language country specific terminology and other opti...

Страница 15: ...menu items are numbered from 1 to 4 Press the button to move to the previous setup menu item Press the button to move to the next setup menu item For example to move from 2 USER OPTIONS to 3 COMMUNICA...

Страница 16: ...2 Depending on how the Weigh Scale was previously set up either the Drafting Off or the Two Way Drafting screen will display 3 Depending on the screen displayed do one of the following If the Draftin...

Страница 17: ...ton 3 The current drafting limit will display on a screen that looks similar to that below 4 Press the button to enter the edit mode The screen will change to look like that below 5 Press the or butto...

Страница 18: ...elow for more information on each of the User Options Press to save the displayed user options and return to the setup menu Weight units You can specify whether the Weigh Scale uses kilograms kg or po...

Страница 19: ...Communications screen select 3 COMMUNICATIONS from the setup menu To change the port setting follow these steps 1 Press the button repeatedly until the required option is selected 2 Press to save the...

Страница 20: ...y in which the Weigh Scale will be used Selecting a country changes the language and sets some country specific terminology and options To display the Select Country screen choose SELECT COUNTRY from...

Страница 21: ...the battery charger or connect to a 12 volt battery If you are not connecting to an external power source the Weigh Scale s internal battery should be fully charged Refer to Charging the battery p 5...

Страница 22: ...te for the weight of any accumulation of mud or dung left on the platform If it succeeds the Weigh Scale displays a zero icon If it does not you can manually restore zero by pressing the blue zero but...

Страница 23: ...tatistics The displayed weight continues to reflect the actual weight on the platform In Fine mode automatic zero tracking is switched off This means the Weigh Scale does not automatically compensate...

Страница 24: ...nformation similar to that shown below In the example above the drafting limit was set to 300 kg Six animals weighed below 300 kg These had an average weight of 292 kg and a total weight of 1753 kg Ei...

Страница 25: ...erator presses the green button You can delete a captured weight from the statistics at two stages during a weighing session while the animal or static load is still supported by the platform or immed...

Страница 26: ...before the next animal steps onto the platform you have an opportunity to delete from the statistics the weight just captured To delete the weight press the red delete button The last captured weight...

Страница 27: ...before another load is placed on the platform you have an opportunity to delete from the statistics the weight just captured To delete the weight press the red delete button The last captured weight...

Страница 28: ...eps 1 Set the mode select switch to the Automatic Manual or Fine weighing mode 2 Press the button After you press the button all values will be set to zero and the lower screen will display as shown i...

Страница 29: ...blue Zero button 4 Load the animal onto the platform Ensure the animal is entirely supported by the platform no hooves on the ground and that no object is restraining or resting on the animal 5 The W...

Страница 30: ...weight replaces the original weight and the statistics are updated 8 Record the weight 9 Move the animal off the platform After the animal has left the platform the following events occur The red lig...

Страница 31: ...ain The new weight replaces the original weight and the statistics are updated Weight on scale memory The Weigh Scale remembers the weight on the display at the time it is switched off This weight is...

Страница 32: ...the weighing mode Automatic and Manual modes In the Automatic and Manual weighing modes zero tracking is automatically implemented if after the animal leaves the weighing platform the residual weight...

Страница 33: ...printer with the Weigh Scale W310 v2 scale Printing weights during a weighing session To print each weight during a weighing session follow these steps 1 Connect the printer cable to the port on the W...

Страница 34: ...Scale 2 Turn the mode select switch to S to display the setup menu 3 Select 3 COMMUNICATIONS 4 Ensure the port is set to Printer 5 Press to return to the setup menu 6 Select the required weighing mod...

Страница 35: ...ed top mounting holes fit all sizes of platforms and crushes 6m 20 long tough loadbar cables fitted with high quality connectors Fully waterproof No rubber mounts Talk to your Gallagher dealer about t...

Страница 36: ...ase of bolting down 6 m 20 long tough loadbar cables fitted with high quality connectors Fully waterproof No rubber mounts High capacity load cells withstand large shock loads Heavy steel chassis cons...

Страница 37: ...ct sturdy design No rubber to delaminate or rot Spiral spring metal reinforced cable High quality moisture proof connectors Gallagher Suspension Load Cell 500 kg Features 500 kg capacity loadcells Rep...

Страница 38: ...mensions Metric Imperial Length 232 mm 9 25 Width 212 mm 8 5 Height 90 mm 3 5 Weight 2 kg 4 4 lb General Operating Temperature 20 to 50 C 5 to 120 F Accuracy 1 Environmental Protection Rating IP65 Inp...

Страница 39: ...Duty Loadbars 4500 kg Automatic or Manual modes 0 49 9 kg 200 g increments 500 g increments 50 199 9 kg 500 g increments 500 g increments 200 499 9 kg 1 kg increments 1 kg increments 500 1999 9 kg 2...