background image

 

 

 

3Ennnn Gallagher T30 Reader Installation Note| DRAFT2 | July 2020 
Copyright © Gallagher Group Limited 

Page 7 

4

 

Installation 

The Gallagher T30 Keypad Reader can be mounted on: 

 

a vertical, rectangular 50 mm x 75 mm (2 in x 3 in) flush box 

 

a BS 4662 British Standard square flush box 

 

any solid flat surface 

The recommended mounting height for the terminal is 1.1 m (3.6 ft) from the floor level to the centre of 
the terminal.  However this may vary in some countries and you should check local regulations for 
variations to this height. 

Notes:

   

 

Consideration should be given to the installation environment when using Bluetooth® enabled 
readers, as the read range may be reduced. 

 

Installation on metal surfaces, particularly those with a large surface area will reduce read range.  
The extent to which the range is reduced will depend upon the type of metal surface.  A spacer 
(C300318 or C300319) can be used to help mitigate this issue. 

 

A black dress plate (C300326) can be used to cover previously installed terminals ensuring a clean 
finish for sites handling an upgrade. 

 

When mounting on a flush box, the corner screws must be used as well as the flush box screws.  
Without corner screws the top of the product is vulnerable to separation from the wall. 
 

1.

 

Ensure the building cable has been run out through the flush box. 

If you are not mounting to a flush box, use the terminal bezel as a guide, to drill all five holes.  Drill the 
13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit 
the mounting surface) and the four corner fixing holes.  Ensure the centre hole allows the cable to run 
freely out through the mounting surface, so that the terminal facia can clip into the bezel. 

Note: 

 There is no room for the building cable to be squeezed into the terminal bezel.  The building 

cable must remain within the flush box or wall cavity. 

2.

 

Run the building cable through the terminal bezel. 

Note: 

 If the terminal has already been connected to the building cable, you can pass the facia 

through the bezel.  Care must be taken to avoid scratching the screen and keypad when passing the 
facia through the bezel. 

3.

 

Secure the bezel to the flush box using the two screws provided. 
When securing the bezel to a vertical, rectangular flush box, use the 6-32 UNC screws provided.  
When securing the bezel to a BS 4662 British Standard square flush box, use the M3.5 screws provided. 

Содержание T30

Страница 1: ...y 2020 Copyright Gallagher Group Limited Page 1 Gallagher T30 Keypad Reader Installation Note T30 MULTITECH Keypad Reader Black C300490 T30 MULTITECH Keypad Reader White C300491 T30 MIFARE Keypad Read...

Страница 2: ...mpleteness and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Nei...

Страница 3: ...ted Page 3 Contents 1 Introduction 4 2 Before you begin 4 2 1 Shipment contents 4 2 2 Power supply 4 2 3 Cabling 4 3 Distance between readers 6 4 Installation 7 5 LED indications 10 6 Accessories 10 7...

Страница 4: ...hillips drive fixing screws 1 x M3 Torx Post T10 Security screw 2 2 Power supply The Gallagher T30 Keypad Reader is designed to operate over a supply voltage range of 9 16 Vdc measured at the readers...

Страница 5: ...one physical location The end devices on the HBUS cable should be terminated using 120 ohms resistance To terminate the Gallagher Controller 6000 connect the supplied on board termination jumpers to...

Страница 6: ...types for optimal HBUS RS485 performance Not applicable for PIV or Bluetooth enabled reader installations Tested with 13 6V at start of cable Notes Shielded cable may reduce the obtainable cable leng...

Страница 7: ...r screws must be used as well as the flush box screws Without corner screws the top of the product is vulnerable to separation from the wall 1 Ensure the building cable has been run out through the fl...

Страница 8: ...rner fixing screws provided Secure the tamper tab located in the bezel to the mounting surface using the remaining fixing screw provided It is important the four corner fixing screws are used to ensur...

Страница 9: ...n into the bezel Note Ensure that there is no pressure upon the wire set as it exits the terminal Ensure the wire set does not exit the reader at a sharp angle as this may compromise the integrity of...

Страница 10: ...Controller but the terminal has no Alarm Zone s assigned to the Alarms Zones property page The terminal screen displays the text Not configured On Green or Red Fully configured and functioning normall...

Страница 11: ...vel Humidity 95 non condensing5 Environmental protection IP68 Impact rating IK09 Unit dimensions Height 118 mm 4 6 in Width 86 mm 3 4 in Depth 25 mm 1 0 in Maximum number of readers on one HBUS cable...

Страница 12: ...o provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accorda...

Страница 13: ...nnn Gallagher T30 Reader Installation Note DRAFT2 July 2020 Copyright Gallagher Group Limited Page 13 9 Mounting Dimensions IMPORTANT This picture is not to scale therefore use the measurements provid...

Отзывы: