Page 8
3E4720 Gallagher T12 Reader | Edi on 12 | May 2023
Copyright © Gallagher Group Limited
An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (a ached to
a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (a ached
to a Controller 6000) or a Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI).
HBUS Reader connec
on:
HBUS
Reader
terminated:
Posi ve
Red
Nega ve
Black
HBUS Termina on Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue
HBUS R
eader
Posi ve
Red
Nega ve
Black
HBUS Termina on Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue
HBUS R
eader
Note:
To terminate an HBUS Reader, connect the
Orange
(HBUS Termina on) wire to the
Green
(HBUS A) wire.
Cardax IV Reader connec on:
Posi ve
Red
Nega ve
Black
HBUS Termina on Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue
Car
da
x IV R
eader
5.
Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding
the top, press the bo om of the facia assembly down into the bezel.
6.
Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
hole at the bo om of the bezel to secure the facia assembly.
Note:
The Torx Post Security screw needs only to be lightly ghtened.
Bezel
Fit screw to secure facia to bezel
Connec on
Reader tail
Building cable
Facia
7.
Removal of the facia assembly is a simple reversal of these steps.
8. Con
fi
gure the reader in Command Centre. If the reader is connected as an HBUS Reader, refer to
the topic
"Con
fi
guring HBUS Devices"
in the Command Centre Con
fi
gura on Client Online Help.
If the reader is connected as a Cardax IV Reader, refer to the topic
"Crea
Ɵ
ng Readers"
in the
Command Centre Con
fi
gura on Client Online Help.