8
CHECKING YOUR FENCE AND
FINDING FAULTS
1.
Place the fence wire in the fence connections slot
while holding the remote as shown below.
2.
Hold until the following information appears on the
display.
Handy Hint:
For best performance, you must be
standing on the ground, and your fingers must make
good contact with the battery cover.
Gives the current on the fence in Amps
Arrow shows
direction of current
on the fence and
fault direction
Gives the Voltage
on the fence in kilo
Volts
The current reading (Amps) will be high when there is a
fault on the fence.
1.
Following the direction of the current, take readings
approximately every 50 - 100m or at junction points
along your fence line.
Note: At a junction point, follow the wire with the
highest current flow.
How to find faults on your fence
IMPORTANT
:
Always grip your
i-Series Remote
firmly, with
your fingers in
contact with the
battery cover,
to avoid a mild
fence shock.
!