be constructed so as to ensure that these wires are positioned at a minimum distance of 150 mm from 

the vertical plane of the non-electrified wires. The barbed wire and razor wire shall be earthed at regular 

intervals.

• 

Follow the energizer manufacturer’s recommendations regarding earthing.

• 

A distance of at least 10 m shall be maintained between the energizer earth electrode and any 

other earthing  system connected parts such as the power supply system protective earth or the 

telecommunication system earth.

• 

Connecting leads that are run inside buildings shall be effectively insulated from the earthed structural 

parts of the building. This may be achieved by using insulated high voltage cable.

• 

Connecting leads that are run underground shall be run in conduit of insulating material or else insulated 

high voltage lead-out cable shall be used. Care must be taken to avoid damage to the connecting leads due 

to the effects of animal hooves or tractor wheels sinking into the ground.

• 

Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication 

cables or data cables.

• 

Connecting leads and electric animal fence wires shall not cross above overhead power or communication 

lines.

• 

Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be 

avoided it shall be made underneath the power line and as nearly as possible at right angles to it.

• 

If connecting leads and electric animal fence wires are installed near an overhead power line, the 

clearances shall not be less than those shown in the table below.

Minimum clearances from power lines for electric animal fences

Power line Voltage V

Clearance m

Less than or equal to 1 000

3

Greater than 1 000 and less than or equal to 33 000

4

Greater than 33 000

8

• 

If connecting leads and electric animal fence wires are installed near an overhead power line, their height 

above the ground shall not exceed 3 m.

This height applies either side of the orthogonal projection of the outermost conductors of the power line 

on the ground surface, for a distance of:

 -

2 m for power lines operating at a nominal voltage not exceeding 1 000 V;

 -

15 m for power lines operating at a nominal voltage exceeding 1 000 V.

• 

Electric animal fences intended for deterring birds, household pet containment or training animals such as 

cows need only be supplied from low output energizers to obtain satisfactory and safe performance.

• 

In electric animal fences intended for deterring birds from roosting on buildings, no electric fence wire 

shall be connected to an earth stake. A warning sign shall be fitted to every point where persons may gain 

ready access to the conductors.

• 

Where an electric animal fence crosses a public pathway, a non-electrified gate shall be incorporated in the 

electric animal fence at that point or a crossing by means of stiles shall be provided. At any such crossing, 

the adjacent electrified wires shall carry warning signs.

•  Any

 

part of an electric animal fence that is installed along a public road or pathway shall be identified by 

electric fence warning signs (G6020) at regular intervals that are securely fastened to the fence posts or 

firmly clamped to the fence wires.

Содержание G34610

Страница 1: ...Instructions Instrucciones ENG ESP PORTABLE SOLAR FENCE ENERGIZER S100...

Страница 2: ...DISCLAIMER Whilst every e ort has been made to ensure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decis...

Страница 3: ...Table of Contents English 4 Espa ol 13 Earth Stake Red Green Red Green 360O MOUNTING RED GREEN EARTH STAKE RED...

Страница 4: ...should penetrate the ground to a depth of at least 1 m 3 ft Fence wiring should be installed well away from any telephone or telegraph line or radio aerial Electric animal fences and their ancillary e...

Страница 5: ...res are installed near an overhead power line the clearances shall not be less than those shown in the table below Minimum clearances from power lines for electric animal fences Power line Voltage V C...

Страница 6: ...equipment unless this equipment is certified by the manufacturer as being suitable for use outdoors and is of a type with a minimum degree of protection IPX4 This energizer complies with internationa...

Страница 7: ...an so battery will charge from the sun 5 Earth Terminal Connects to earth ground stake 6 Fence Terminal Connects to fence 7 Voltage Indicator Green pulse Fence Voltage is OK Red pulse Fence voltage is...

Страница 8: ...s the equator i e in the northern hemisphere panel faces south in the southern hemisphere panel faces north Avoid placing in a shady area 5 Connect leads a Connect green terminal to earth stake at lea...

Страница 9: ...to control nocturnal animals Full Power The energizer slows the pulse rate at night to conserve power allowing it to deliver a higher energy pulse during the day when animals are active Note In prolo...

Страница 10: ...ery to charge Ensure energizer is getting enough sun Turn energizer off for 3 days leave in sun to charge battery Connect Recharge Kit G40110 to charge battery Battery indicator flashes red No battery...

Страница 11: ...arged Recharge battery before and after storage Maintenance free battery The battery must not be opened and does not require maintenance Battery replacement Use only 12 V 7 Ah sealed valve regulated V...

Страница 12: ...duct indicates that this product packaging and with special care of the battery must not be disposed of with other waste Instead it is your responsibility to dispose of your waste equipment by handing...

Страница 13: ...el cable de corriente otros cables alambres y el energizador Si encuentra alg n da o detenga inmediatamente su uso y env e el energizador a un Servicio T cnico Autorizado de Gallagher para su reparac...

Страница 14: ...efectiva de partes estructurales conectadas a tierra de dichas edificaciones Esto puede lograrse utilizando cable de alta tensi n Los cables de conexi n que van por debajo del suelo deben ir en un mat...

Страница 15: ...RECAUCI N Cerca el ctrica o El s mbolo mostrado La inscripci n debe ser indeleble escrita por ambos lados de la se al de aviso y tener una altura de por lo menos 2 5 mm Aseg rese de que el equipo auxi...

Страница 16: ...ejos y Resoluci n de Problemas p 20 2 Interruptor de encendido Revisi n de la bater a OFF Energ a media Energ a m xima 3 Sensor de luz Utilizado para determinar si es de d a o de noche 4 Panel solar M...

Страница 17: ...esoluci n de Problemas p 20 8 Orificios de montaje 9 Acceso a la bater a Desatornille para acceder a la bater a la bater a necesita conectarse antes del primer uso 10 Instalaci n poste de acero Permit...

Страница 18: ...rte el panel est orientado hacia el sur en el hemisferio sur el panel est orientado hacia el norte Evite colocarlo en una zona sombr a 5 Conecte los cables a Conecte el terminal verde a la estaca de t...

Страница 19: ...es Posici n de Encendido Descripci n Energ a media El energizador emite impulsos r pidamente de d a y de noche para controlar animales nocturnos Energ a m xima El energizador reduce los impulsos duran...

Страница 20: ...continuo La capacidad de la bater a es baja debido a la insuficiencia de luz solar El generador se ralentizar para utilizar menos energ a y permitir que la bater a se recargue Aseg rese de que el ene...

Страница 21: ...o por un rayo Compruebe que el energizador no est averiado desconecte de la cerca y de la tierra efect e mediciones en todos los terminales de la cerca y tierra con el volt metro Gallagher Fence Volt...

Страница 22: ...i n para que el panel solar antenga labater a cargada Recargue la bater a antes y despu sdel almacenamiento Bater a libre de mantenimiento La bater a no debe abrirse y no requiere mantenimiento Reempl...

Страница 23: ...35 2 76 APAVE 9609187 001 1 B DESECHO DE COMPONENTES Y EQUIPOS ELECTR NICOS Este s mbolo en el producto indica que dicho producto embalaje y por sobre todo la bater a no debe ser desechado con otros d...

Страница 24: ......

Страница 25: ...producto en internet en www gallagherams com y benef ciese de las siguientes ventajas Un servicio de atenci n al cliente y un soporte t cnico tiles Un registro que puede ser de ayuda si pierde o le r...

Страница 26: ...SP CONDICIONES DE LA GARANT A Se garantiza este producto frente a defectos en el material o en la mano de obra durante un periodo de un a o a partir de la fecha en que el usuario final compr el produc...

Отзывы: