5.

 

Connect the terminal tail extending from the facia assembly to the building cable.   

An HBUS device connects to a Gallagher Controller 6000, Gallagher 4H/8H Module, a Gallagher HBUS 
Door Module, or a Gallagher HBUS 8 Port Hub. 

HBUS connections: 

 

 

 

HBUS connections terminated: 

 

To terminate an HBUS device, connect the 

Orange

 (HBUS Termination) wire to the 

Green

 (HBUS A) 

wire. 

 

PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only. 

6.

 

Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding the 
top, press the bottom of the facia assembly down into the bezel. 

Note:  

Ensure that there is no pressure upon the wire set as it exits the terminal.  Ensure the wire set 

does not exit the reader at a sharp angle, as this may compromise the integrity of the wire set's water 
seal. 

7.

 

Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the hole 
at the bottom of the bezel to secure the facia assembly.   

Note: 

 The Torx Post Security screw needs only to be lightly tightened. 

8.

 

Removal of the facia assembly is a simple reversal of these steps. 

9.

 

Configure the terminal in Command Centre.  If the terminal is connected as an HBUS device, refer to 
the topic 

"Configuring an HBUS Terminal"

 or the topic 

"Configuring the PIV Card Reader"

 in the 

Command Centre Configuration Client Online Help.  If the terminal is connected as a Cardax IV device, 
refer to the topic 

"Creating Readers"

 in the Command Centre Configuration Client Online Help. 

 

 

Содержание C300490

Страница 1: ...y 2020 Copyright Gallagher Group Limited Page 1 Gallagher T30 Keypad Reader Installation Note T30 MULTITECH Keypad Reader Black C300490 T30 MULTITECH Keypad Reader White C300491 T30 MIFARE Keypad Read...

Страница 2: ...mpleteness and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Nei...

Страница 3: ...ted Page 3 Contents 1 Introduction 4 2 Before you begin 4 2 1 Shipment contents 4 2 2 Power supply 4 2 3 Cabling 4 3 Distance between readers 6 4 Installation 7 5 LED indications 10 6 Accessories 10 7...

Страница 4: ...hillips drive fixing screws 1 x M3 Torx Post T10 Security screw 2 2 Power supply The Gallagher T30 Keypad Reader is designed to operate over a supply voltage range of 9 16 Vdc measured at the readers...

Страница 5: ...one physical location The end devices on the HBUS cable should be terminated using 120 ohms resistance To terminate the Gallagher Controller 6000 connect the supplied on board termination jumpers to...

Страница 6: ...types for optimal HBUS RS485 performance Not applicable for PIV or Bluetooth enabled reader installations Tested with 13 6V at start of cable Notes Shielded cable may reduce the obtainable cable leng...

Страница 7: ...r screws must be used as well as the flush box screws Without corner screws the top of the product is vulnerable to separation from the wall 1 Ensure the building cable has been run out through the fl...

Страница 8: ...rner fixing screws provided Secure the tamper tab located in the bezel to the mounting surface using the remaining fixing screw provided It is important the four corner fixing screws are used to ensur...

Страница 9: ...n into the bezel Note Ensure that there is no pressure upon the wire set as it exits the terminal Ensure the wire set does not exit the reader at a sharp angle as this may compromise the integrity of...

Страница 10: ...Controller but the terminal has no Alarm Zone s assigned to the Alarms Zones property page The terminal screen displays the text Not configured On Green or Red Fully configured and functioning normall...

Страница 11: ...vel Humidity 95 non condensing5 Environmental protection IP68 Impact rating IK09 Unit dimensions Height 118 mm 4 6 in Width 86 mm 3 4 in Depth 25 mm 1 0 in Maximum number of readers on one HBUS cable...

Страница 12: ...o provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accorda...

Страница 13: ...nnn Gallagher T30 Reader Installation Note DRAFT2 July 2020 Copyright Gallagher Group Limited Page 13 9 Mounting Dimensions IMPORTANT This picture is not to scale therefore use the measurements provid...

Отзывы: