17
English
3E4723 Gallagher MBS100 MBS200 MBS400 MBS800 Multi-Power User Manual
TIPS & TROUBLESHOOTING
•
Turn off energizer before handling fence or battery connections.
•
Install solar energizers on a post above the ground.
Symptom
Problem
Solution
Energizer has
started to
run slowly
The internal
temperature of the
energizer is too high
Mount the energizer in a cool area, out of
direct sunlight and with adequate ventilation.
Low battery capacity
Check battery voltage using the battery check
mode. Replace with fully charged battery or
ensure solar panel is getting enough sun to
allow batteries to charge.
Energizer
does not
operate
Battery has less
than 10% capacity
remaining
Replace with fully charged battery or ensure
solar panel is getting enough sun to allow
batteries to charge.
Energizer is Off
Check power source is connected. Ensure
mode selector switch is ON.
Faulty energizer
Have energizer repaired.
Electric fence
voltage is
below 3000V
or your stock
are escaping
Faulty energizer
Disconnect energizer from fence and earth.
Measure across the fence and earth terminals
using a Gallagher fence volt meter. If the
voltage is less than 5000v, have energizer
repaired.
Inadequate earthing
Improve the earth system by adding more
galvanised earth stakes to the earth system
until the earth voltage is 200V or below.
Loose connections
Check the electrical connections are secure e.g.
from the fence to the red terminal, from the
earth system to the green terminal, at gates
etc.
Содержание 389318