Galiso OPTI-LITE Скачать руководство пользователя страница 15

 

Section 5 – 4 

21-11-1180 

 

5.0 MAINTENANCE, continued

 

 

5.5 Troubleshooting, continued 

 

C.  The Light briefly turns on and then off; Fan operates 

1.  The Lamp may have a faulty filament. Turn the Intensity Control Knob to 

maximum setting to the test lamp. 

2.  If the Lamp fails, replace the Lamp (See 5.2 Lamp Replacement). 

3.  Examine the Lamp Socket assembly for damage and continuity. 

 

D.  The Light will not turn on, Fan operates 

1.  Replace the Lamp (See 5.2 Lamp Replacement). 

 

E.  The Light is dim or non-existent; Fan does not operate 

1.  Make sure to use the correct model for the power available. Running a 240v 

unit in 120/100v conditions will stop the fan and dim the lamp. 

 

F.  The Light is on; Fan does not operate 

1.  Return to Galiso, Inc. by calling (800) 854-3789 to receive a return 

authorization number and shipping instructions. 

 

G.  The Light is off; Fan does not operate 

1.  Make sure the power cord is inserted completely into the IEC connector and 

also into the correct power source. 

2.  Check the power cord for damage. 

3.  Check the fuse. 

 

H.  The Light Guide is burning 

1.  Check the fiber type. If a Light Guide is in use that is not a Galiso, Inc. fiber 

optic Light Guide, it may be plastic and susceptible to burning. Using a glass 

fiber Galiso, Inc. Light Guide is recommended. 

2.  Some epoxy types cannot withstand the high temperatures developed in the 

light source. Call the supplier if there is any question as to the epoxy used to 

manufacture the fiber optic input. 

3.  Check the Lamp type. Replace the Lamp with Galiso, Inc. approved part 

number: 85-11-0028, EKE 150W, (See Table 5-1, Spare and Accessory 

Parts). Light Guides damaged by use of non-approved Lamps will void the 

fiber warranty. 

 

 

 

 

Содержание OPTI-LITE

Страница 1: ...ER OPTIC LIGHT GUIDE INSTRUCTION MANUAL MANUAL NUMBER 21 11 1180 Revision A Issued July 2013 Revised March 2022 Copyright 2013 Galiso Inc 22 Ponderosa Ct Montrose CO 81401 970 249 0233 800 854 3789 ww...

Страница 2: ...LITE Operations 4 1 4 1 Operation 4 1 4 2 Intensity 4 1 5 0 Maintenance 5 1 5 1 General 5 1 5 2 Lamp Replacement 5 1 5 3 Fuse Replacement 5 1 5 4 Nosepiece Adapter Insert 5 2 5 5 Troubleshooting 5 3...

Страница 3: ...DANGER DO NOT USE THIS EQUIPMENT TO PURGE TOXIC OR FLAMMABLE GAS AND DO NOT USE THIS EQUIPMENT UNDER FLAMMABLE VOLATILE OR TOXIC ENVIRONMENTAL CONDITIONS...

Страница 4: ...The light source is CSA listed to UL 1571 120 V version The updated OPTI LITE features an ergonomic Handle a Nosepiece Adapter with locking design to keep Light Guides steady and Intensity Control fro...

Страница 5: ...i Lite Kit Note Light Guide Receptacle showing without adapter Illuminator Box Overall Height 4 9 125 mm Overall Width 8 205 mm Overall Depth 7 180 mm Unit Weight 9 9 lbs 4 5 kg including cord Light G...

Страница 6: ...lace the device next to other sensitive electronic devices Failure to do so could result in errant operation of the nearby device D Avoid using or storing the OPTI LITE in or on areas of excessive vib...

Страница 7: ...f power the OPTI LITE will remain off when power is restored to the unit When power is returned turn the Intensity Knob to OFF and then slowly turn up intensity until light is returned L Do not defeat...

Страница 8: ...e 3 1 Minimum Clearance B Ensure the Lamp has not been dislodged from the Lamp Holder during shipment by opening up the Lamp Replacement Door and visually inspecting the Lamp The Lamp should fit symme...

Страница 9: ...Section 3 2 21 11 1180 This page intentionally left blank...

Страница 10: ...ol down time of one to two minutes before turning the unit off C After the above steps have been performed the Light Guide can be inserted into the cylinder neck to proceed with inspections Always avo...

Страница 11: ...Section 4 2 21 11 1180 This page intentionally left blank...

Страница 12: ...nally dust should be removed from the Illuminator Box by using vacuum or commercial can of compressed air Pay special attention to the fan blades at the rear of t unit and the air vents in the front a...

Страница 13: ...mic Lamp Socket See Figure 5 1 Lamp Replacement Note Remember to never touch the Bulb or the Reflector in the Lamp Only touch the sides when inserting a new Lamp E Insert a new Lamp into the Lamp Brac...

Страница 14: ...B To install the new Nosepiece Adapter unscrew all three Thumb Screws Turn the Illuminator Box over to allow the Adapter to fall out Insert the new Nosepiece Adapter and re tighten the Thumb Screws 5...

Страница 15: ...800 854 3789 to receive a return authorization number and shipping instructions G The Light is off Fan does not operate 1 Make sure the power cord is inserted completely into the IEC connector and als...

Страница 16: ...x 20 L 3 85 11 0043 Light Guide 1 4 x 5 ULG 4 85 11 0050 Light Guide 1 4 x 6 L 5 85 11 0061 Light Guide 1 8 x 5 L 6 85 11 0062 Light Guide 1 8 x 10 L 7 85 11 0063 Light Guide 1 4 x 5 L 8 85 11 0064 L...

Страница 17: ...Section 5 6 21 11 1180 This page intentionally left blank...

Страница 18: ...equipment malfunction notify Galiso 1 800 854 3789 and provide the Model Name Model Number Serial Number and a description of the problem Return Authorization Number shipping and or service informati...