background image

 
 

GALISO SOAP OPTION

 

FOR PCT-ADW-D 

 
 

Installation and Operation Instructions

 

 

 

 
 
 
 
 

 
 
 

MANUAL NUMBER 21-11-1008 

 

Issued March 2016 

 
 

Rev B 

09/26/2018 

 

 

Copyright 2016 - Galiso, Incorporated 

22 Ponderosa Ct.,  Montrose, CO  81401 

(970) 249-0233   (800) 854-3789 

www.galiso.com 

Содержание 21-11-1008

Страница 1: ...R PCT ADW D Installation and Operation Instructions MANUAL NUMBER 21 11 1008 Issued March 2016 Rev B 09 26 2018 Copyright 2016 Galiso Incorporated 22 Ponderosa Ct Montrose CO 81401 970 249 0233 800 85...

Страница 2: ...DANGER DO NOT USE THIS EQUIPMENT TO PURGE TOXIC OR FLAMMABLE GAS AND DO NOT USE THIS EQUIPMENT UNDER FLAMMABLE VOLATILE OR TOXIC ENVIRONMENTAL CONDITIONS...

Страница 3: ...2 0 Installation 2 1 ILLUSTRATIONS Title Page Soap Option Kit Parts 1 1 Item A Valve and Hex Bushing 2 1 Item B Bronze Piston Valve Assembly 2 1 Item C Check Valve Hex Bushing and Tube Fitting 2 2 It...

Страница 4: ...Placement A Carefully unpack the Soap Option Kit and inspect the items for any damage or missing parts Report any issues to Galiso incorporated before installing on the PCT 1 0 Kit Parts A Valve and h...

Страница 5: ...1008 2 0 Installation A Install the Valve and Hex Bushing item A onto the left side of the PCT enclosure where indicated Item A B Install the Bronze Piston Valve Assembly item B on the inside of the...

Страница 6: ...ce with item C Hex Bushing Check Valve and Tube Fitting Item C D Remove the Valve Stack Cover Locate the Blank located in slot two and loosen the single Mounting Screw The Blank should now lift out ea...

Страница 7: ...om Galiso Incorporated at 800 854 3789 or visit the website at www galiso com NOTE Certain types of detergents and cylinder cleaning solutions are not compatible with aluminum cylinders Galiso Inc rec...

Страница 8: ...ergent Reservoir Clean Air Supply Line can originate from the clean air source supplying the PCT A filter system is available from Galiso Inc which will clean the air to a contaminant level of 0 01 pa...