Command format
MainPack bbbbbbbbbbbbbb
Parameters
bbbbbbbbbbbbbb – tag set.
If b is replaced by 1, the tag is on.
If b is replaced by 0 the tag is off.
Tag numeration order is given in section
Explanation
Main packet configuring.
Example
Request: MainPack 11111111111111111111110000
Reply: MainPack= 00000000000000000000011111111111111111111110000b
This means that tags 1, 2, 3, 4 are off and tags 5-26 inclusive are on. All the following tags
are off.
Command format
MainPackBit index,value
Parameters
index –tag number, which is on or off for transmission to the server
value – 1 if this tag should be transmitted to the server
0 if this tag should not be transmitted to the server
Tag numeration order is given in section
Explanation
Main packet configuring.
Example
Initially the second tag is off:
HeadPack=1100b
Switch on this tag.
Request: HeadPackBit 2,1
Reply: HeadPack=1100b
Command format
DataKey key
Parameters
Key – data encryption key in hexadecimal form, if it is equal to 0, data are not encoded.
Explanation