operates, then water will eject from the 
bottom of the unit.
Should this happen, turn off the 
electricity and water supplies to the 
shower at the isolating switch and 
stopvalve. Contact Customer Service
for advice on replacing the PRD.
The PRD is situated adjacent to the 
outlet pipe 

(Fig.4)

.

To gain access to it, FIRST SWITCH 
OFF THE ELECTRICITY SUPPLY, 
remove the cover, then unscrew using
suitable wrench or grips.

CAUTION: Do not attempt to replace 
the PRD unless competent to do so.

NOTE: Before replacing the cover, it is 
strongly advised to prime the unit (see 
‘commissioning’).

Allow sufficient room between the ceiling 
and the shower to access the cover top 
screws.

8

SECTION

PRESSURE RELIEF SAFETY
DEVICE

A pressure relief device (PRD) is 
designed into the shower unit which 
complies with European standards. 
The PRD provides a level of appliance
protection should an excessive build up 
of pressure occur within the shower.

DO NOT operate the shower with a 
damaged or kinked shower hose, or a 
blocked sprayhead which can cause the 
PRD to operate.

When commissioning, the sprayhead 
must be removed from the flexible hose. 
Failure to follow this procedure may also 
result in causing the PRD to operate.
Ensure the shower is positioned over a 
bath or shower tray because if the PRD

PRD

9

SECTION

FITTING THE SHOWER TO
THE WALL

NOTE: The control knobs are an integral 
part of the cover – do not attempt to 
remove them.

IMPORTANT: 

The unit must be mounted 

on a flat surface which covers the full 
width and length of the backplate. It is 
important that the wall surface is flat 
otherwise difficulty may be encountered
when fitting the cover and subsequent 
operation of the unit may be impaired.

Fig.3

Fig.4

‘COLD' position and the temperature 
control is at ‘TEMPERATURE’.

Replace the cover squarely to the 
backplate and guide into position so that 
the controls locate correctly into the 
spindles while at the same time, ensuring 
wires are not trapped. Should any 
difficulty arise, re-check the points above

Secure the cover in position with the
four retaining screws.

 DO NOT 

OVERTIGHTEN.

.

Fig.12

Fig.18

Fig.17

Fig.16

Switch on the mains electric supply to the 
shower at the isolating switch.

Press the ‘START/STOP’ button 

(Fig.17). 

The power indicator will light and the 
pump starts to operate.

It will take approximately thirty seconds 
for a smooth flow of water to be obtained 
whilst air and any debris is being 
dispersed from the shower. When a 
smooth flow of water is obtained, rotate
the temperature control from ‘1’ to ‘10’ 
several times 

(Fig.18) 

to release any 

trapped air within the unit.

Once flushing out has been completed, 
stop the water flow by pressing the 
‘start/stop’ button.

Because the shower is fitted with Phased
(Safety) Shutdown, the indicator light will
begin flash and water flow will be reduced
for approx 8 seconds before the shower 
switches off. During this Phased (Safety) 
Shutdown, power to the heating elements
is cut. This allows the unit to safely 
disipate any residual heat.  

Commissioning is complete. Once the 
riser rail is fitted, the shower is ready for 

13

SECTION

RISER RAIL & SOAP DISH
FITTING INSTRUCTIONS

TIPS

A piece of insulating or masking tape 
applied to the wall before marking out the
fixing holes will help stop the drill from 
wandering, particularly on tiled surfaces.
When working near a basin or bath, insert
the plug in the waste fitting so that small
parts cannot be lost. Take care not to drop 
accessories or tools into basin or bath.

Содержание Aqua 9000 XP

Страница 1: ...ower rating serial number and date of purchase The Galaxy Technical Hotline will be able to inform you whether the fault can be rectified by the provision of a replacement part or an on site visit by...

Страница 2: ...ructions Any component found to be defective during this period as the result of misuse or damage or the effects of scaling will not be covered by this guarantee with the exception of si Scalemaster m...

Страница 3: ...ness is sufficient 6 Al plumbing connections MUST be completed BEFORE making the electrical connections ELECTRICAL 1 The installation must comply with BS 7671 Requirements for electrical installations...

Страница 4: ...5kW 40A MCB rating 9 5kW 40A MCB rating Nominal power rating at 230V 8 5kW 40A MCB rating 9 5kW 40A MCB rating The following points will help you understand how the shower operates A The electric heat...

Страница 5: ...0 08 METRES RATING 20 MINS ON 60MINS OFF RATED PRESSURE 0 Pa THIS SHOWER UNIT WILL NOT EXCEED A FLOW RATE OF 20 LPM GALAXY SHOWERS COVENTRY UK REGISTERED DESIGN Model AQUA 9000XP 8 5KW 240V IPX4 SERI...

Страница 6: ...uit protection See table B 19 To obtain full advantage of the power provided by the shower use the shortest cable route possible from the consumer unit to the shower 20 It is also necessary to satisfy...

Страница 7: ...MUST be positioned vertically 7 SECTION SITING OF THE SHOWER Fig 2 CAUTION Check there are no hidden cables or pipes before drilling holes for wall plugs Exercise great care when using power tools nea...

Страница 8: ...cover and subsequent operation of the unit may be impaired Fig 3 Fig 4 COLD position and the temperature control is at TEMPERATURE Replace the cover squarely to the backplate and guide into position s...

Страница 9: ...rst operation of the shower is intended to flush out any remaining unit debris and to ensure the heater unit contains water before the elements are switched on This operation must be carried out with...

Страница 10: ...connecting a hose to the pipework and turning on the water supply long enough to clear the debris to waste Fit the pipework to the inlet elbow Ensure the elbow collet is fully engaged with the pipe A...

Отзывы: