Страница 1: ...1M3S Control Box Wiring Programming Guide...

Страница 2: ...ote s Figure 3 Control Board Figure 8 Magnetic Limit Switch Wired Portion Figure 7 Magnetic Limit Switch Non Wired Portion Figure 6 Magnetic Limit Switch Mounting Bracket Figure 2 Call Send Box Figure...

Страница 3: ...nctions The Gel Pad is the primary control center for your lift The Gel Pad can turn your unit off and on send the unit to its levels or stop the travel in any direction The remotes are programmed fro...

Страница 4: ...ess the up button on each remote once you will see a corresponding flash from the learn LED 4 Give the learn mode 10 seconds to expire you will see a rapid flash from the learn LED 5 Now test the remo...

Страница 5: ......

Страница 6: ...240 Volt standard Lift Wiring CB...

Страница 7: ...e indicated in the Control box door please call our technical support team to receive further instructions Phone 888 317 7203 Inside Motor Wiring Black T1 Orange T4 Red T5 Join T2 T3 T8 Inside Control...

Страница 8: ...120 Volt Standard Lift Wiring CB...

Страница 9: ...rol box door please call our technical support team to receive further instructions Phone 888 317 7203 Inside Motor Wiring Black T1 T3 Orange T2 T4 Red T5 White T8 Inside Control Box Motor Wiring Oran...

Страница 10: ...240V or 120V Overlimit Set Up 1 Connect the black wire from the Overlimit cable to the black wire coming from the 9 Pin Molex connecter 2 Connect the white wire from the Overlimit cable to the black...

Страница 11: ......

Страница 12: ...temporarily mount the Non wired Component of the Magnetic Limit Switch on the outside of one of the external backbones of the cargo lift Either of the two backbones is acceptable but note that the Wi...

Страница 13: ...ence figure 16 below shows the Control Board CB outside the control box Figure 15 shows CB installed inside the control box There are 5 wires Green Blue White Red and Black coming from the middle edge...

Страница 14: ...CB Limits...

Страница 15: ...nnect the green limit wire from the CB to the red wire for the Bottom Mag Note the black wire for the Magnetic Limit Switch is not used 11 Use wire nuts to secure the connections 12 Carefully replace...

Страница 16: ...Additional Equipment Setup Section Not Standard Call Send Station Call Send...

Страница 17: ...ol box while attaching the wires 3 Find the blue screw terminals located near the Gel Pad connector as shown in figure 18 below 4 Connect the wires from the call send station as shown in the figure 18...