XYJGT80QFSDE-001
21
3)In the formal product stage, the software version information is displayed from "000".
6.3
检测模式
Detection mode
将旋钮旋到
P01
位置,同时按住
K1/K2
键,然后插上电源进入检测模式。
Turn the knob to position P01, press and hold the K1 / K2 key at the same time, and then plug in the
power supply to enter the factory mode.
进入测试程序,蜂鸣发出
“
嘟嘟嘟、嘟嘟嘟
”
鸣叫,所有指示灯
/
图标闪烁
3
次,然后熄灭,显示屏剩余
时间显示
“PLt”,
锁门等待选择执行模式。此时若按启停键,程序执行自动检测模式;若旋动旋钮开关则
执行手动检测模式。具体流程如下:
Enter the test program, the buzzer will sound, all indicator lights / icons will flash for 3 times, and then
turn off, the display screen will display "PLT" for the remaining time, lock the door and wait to select
the execution mode. At this time, if you press the start stop key, the program will execute the
automatic detection mode; if you turn the knob switch, the manual detection mode will be executed.
The specific process is as follows:
设定
Set up
描述
Describe
C01
预洗阀测试
(
P02
位置)
C01 pre washing
valve test
(P02 position)
注水设定时间
Water injection setting time
C02
主洗阀测试
(
P03
位置)
C02 main
washing valve
test
(P03 position)
注水设定时间
Water injection setting time
C03
软化阀测试
(
P04
位置)
C03 softening
valve test
(position P04)
注水设定时间
Water injection setting time
C04
热水阀测试
(
P05
位置)
C04 heat washing
valve test
(position P05)
注水设定时间
Water injection setting time
C05
加热测试
(
P06
位置)
C05 heating test
判断水位是否已在加热水位以上,如未到必须先补水至加热水位,然后启动加
热,加热设定时间
Judge whether the water level is above the heating water level, if not, make