![Galanz DV-60Q1E Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/galanz/dv-60q1e/dv-60q1e_service-manual_3234339014.webp)
13
Temperature
sensor
1
.
Whether the temperature sensor is short-circuit
?
2
.All not。
1.Reconnect
2.
Visit replace
Heater
1.Heater is short-circuit?
2.All not。
1.Reconnect
2.Visit replace
Door lock
1.Door is opening。
2.All not。
1.Close the door
2.Visit replace
9
.
Fault diagnosis and repairing
9.1
、
Fault diagnosis and repairing, be careful of electric shock, unplug the power plug before
servicing.
9.2
、
Firstly
,
check the wiring harness connection for each terminal
。
9.3
、
If need to replace the control board, please correct arrange .
9.4
、
Please specific realize the fault before repair
。
No power
1
AC power is measured 220V-240V
?
No connected to right
power source
2
Measure voltage value of control board
,
is the AC voltage
for 220V-240V
?
No check wiring harness
As
3
Replace control board As
。
Abnormal noise
1
Micro- V belt bolts loose
?
Yes Tighten bolts
2
Micro-V belt with wear
?
Yes replace micro-V belt
3
Is it a noise from
Yes replace motor
No heating
1
Is there any problem from temperature sensor?
Yes replace temperature sensor
2
Off the power, measuring heat pipe at both ends of
resistance is between 20-30
?
Yes Normal
3
Replace the heater
。
Door lock fault
1
Is the door closed when start, any E02 or E2 signal?
No close the door
2
Change the door lock
Motor fault
1
Clothes capacity is over loaded when the machine
is operating with the voltage 220-240V
?
Yes reduce clothes
2
Motor connection cable is connected properly
?
No Reconnect
3
Check whether the motor has burned out
?
Yes replace motor
4
All not
,
replace control board
。
10
.DV-60Q1E/DV-60Q1K/DV-60Q1S/DV-60Q2ME/DV-60Q2MK/DV-60Q2MS/