No.
Command
Description
settings
Default
16
21[mode]#
Set Input 2 mode
Mode= 0, 1, 2 or 3
0 = Disable , 1 = Trigger
2 = Egress 1, 3 = Egress2
1
17
27 [mode]#
Set Input 3 mode
Mode= 0 or 1
0 = Disable , 1 = Trigger
1
18
28+IN*time start+ time
end*time start + time
end*……....#
Set time duration ( enable
inputs )
Example:
Enable input 1time duration
00:00~05:00,
12:00~16:00,
21:00~23:00
SMS
format:281*0005*1216*2123#
IN=
1
, 2 or 3
( input 1~3)
Time start = 00~23
Time end = 01~24
( hour as an unit)
enable
19
*31*1234#[ SMS content]#
SMS message to be sent
when input 1 is triggered.
SMS content=max 100
characters
Trigger1
is Active
20
*32*1234#[ SMS content]# SMS message to be sent
when input 2 is triggered.
SMS content=max 100
characters
Trigger2
is Active
21
*33*1234#[ SMS content]# SMS message to be sent
when input 3 is triggered.
SMS content=max 100
characters
Trigger3
is Active
22
71[country code]#
To set country code
Country code= 1-3 digits
(UK:44 / USA:1)
886
23
72[relay][phone number]#
Store phone number
For ringing in to open the
door
(max: 1150 numbers)
Relay= 1 or 2
Phone number =3 ~14
digits
N/A
24
73 [phone number]#
Delete a ring in to open
number
phone number =3 ~14
digits
N/A
25
73*#
Delete all ringing in to open
numbers
26
74[admin number] #
Add administrator phone
number
admin number =3 ~14
digits ( no number no
restriction)
N/A
27
74*#
Delete administrator phone
number