SS1603-01 3G Audio Intercom (E1)
21
17
Disable, enable call
button LED flashing
896+X#
X=0, 1, 2
0: LED ON
1:LED flashing
2:LED OFF
0
18
Dial tone volume
898+X#
X=1~3 ( levels)
2
19
Engress (PB pin on PCB) 900[X]#
X=0 (relay 1)
X=1 ( realy2)
0
20
Engress(
detect pin on
PCB
)
901[X]#
X=0 (relay 1)
X=1 ( realy2)
1
21
Detect pin on PCB setup
902[ X]#
X=0~3
0:disable
1:engress mode (901)
2:trigger
3. Resistance=10K
Ω
(7.5K~13K)
0
22
Intercom move Detection
(Theft Proof)
904[X]#
X=0 (disable)
X=1 (enable)
0
23
Intercom move Detection
Contact number
905[X]#
X=0 (disable)
X=1 (enable)
0
24
Intercom LED light
906[X]#
X=0 (disable)
X=1 (enable)
0
25
Enable or disable IN1
907[X]#
X=0 (disable)
X=1 (enable)
0
26
Send SMS when door is
detected open
*26*[ password ] #SMS
content#
PWD default 1234
SMS content:100 characters
Detect
PIN
Trigger
27
Intercom move detection
SMS content
*27*[ password ]#SMS
content#
PWD default 1234)
SMS content:100 characters
Case open
28
Power loss
SMS content
*28*[ password ]#SMS
content#
PWD default 1234
SMS content:100 characters
Power loss
29
Power active
SMS content
*29*[ password ]#SMS
content#
PWD default 1234
SMS content:100 characters
Power
active
30
Input 1 is trigged
SMS content
*30*[ password ]#SMS
content#
PWD default 1234
SMS content:100 characters
IN1