Single Site Programmer User Guide
1
GS-SNG-SITE-PRG-UG-001240
Page 28 of 30
Release 1.0
Running the GUI
In order to run the software, turn the PROGRAM/RUN switch to PROGRAM mode.
1.
Open the
Single Site Programmer.ini
file. Provide the correct WLAN, APP0 and APP1 file names and
place all three files in the same folder as the program. Enter the COM Port to which the hardware is
connected to.
2.
Save and close the
Single Site Programmer.ini
file.
3.
Open the
Single Site Programmer.exe
(see
Figure 13: Software in Programming Mode
4.
The STATUS box should display
PROGRAMMING MODE. Check if board is in PROGRAM mode. HIT
SPACE to BEGIN
. If the STATUS box doesn’t display this message, close the program and re-edit the
configuration file (see Step 1).
5.
Ensure the Power Switch is
OFF
. Load the module, and toggle the PROGRAM/RUN switch to
PROGRAM
mode.
6.
Switch the power to the
ON
position and hit the space bar.