GAI-Tronics ILC-1117 Скачать руководство пользователя страница 7

ILC-1117 Titan Illuminated Crossing Telephone 

2.  Select the appropriate sized gland: 

Use the smaller gland for cables diameters 4 - 7mm.  
Use the larger gland for cable diameters 8 - 13mm. 

3.  From the outside of the case, insert 

the selected gland into the threaded 
cable entry hole and tighten, so that its 
sealing washer is compressed against 
the enclosure surface.  

4.  Proceed with chosen mounting method 

below 

 

As standard, The telephone is supplied with a pole mounting kit 100-02-0208-
001, but no glands. 

 

4.3.  Wall mounting 

 

1.  Using a suitable tool, punch out 4 holes in the rear enclosure, taking 

care not to damage or dislodge the plastic bushes.  Only four of the 
eight holes are required - the outer ones are recommended.  The 
inner holes are provided to be compatible with older-style mounting 
posts, and should be left intact if not used.  If the inner holes are 
used they must be fitted with the supplied plastic bushes. 

Содержание ILC-1117

Страница 1: ...Doc No 502 20 0132 001 Iss2 Dec 2012 CN37277 002 1 2 3 Press LIFT HANDSET PRESS BUTTON WAIT FOR ANSWER Installation and User Guide ILC 1117 Titan Illuminated Crossing Telephone GAI TRONICS...

Страница 2: ...5 3 2 Handset integrity alert 5 4 Installation 6 4 1 General 6 4 2 If glands are required 6 4 3 Wall mounting 7 4 4 Pole mounting 8 5 Connections and option settings 9 6 Legend Panel 12 6 1 Legend pa...

Страница 3: ...al describes the ILC 1117 model Titan telephone designed for use on PETS Public Emergency Telephone System at automatic half barrier AHB level crossings in the UK The product was introduced with the d...

Страница 4: ...n Illuminated Crossing Telephone 2 2 At a Glance 1 2 3 Press LIFT HANDSET PRESS BUTTON WAIT FOR ANSWER Door Handset Pushbutton Faceplate Illuminated panel Timer Switch Main Terminal Block Legend panel...

Страница 5: ...for call connection timings The loop break duration is independent of how long the button is held pressed Keeping the button pressed will still only result in a 100ms break 3 1 Call timer The phone h...

Страница 6: ...exposed circuit board when setting the faceplate aside during installation Caution take care to support the spring loaded door whilst open to prevent it slamming shut and trapping fingers 2 All connec...

Страница 7: ...rface 4 Proceed with chosen mounting method below As standard The telephone is supplied with a pole mounting kit 100 02 0208 001 but no glands 4 3 Wall mounting 1 Using a suitable tool punch out 4 hol...

Страница 8: ...late for drilling 3 Drill holes in the wall on the marked positions Select appropriate screws wall plugs etc for the type of wall bearing in mind that the weight of the complete phone is around 5kg IM...

Страница 9: ...f 4 5Nm max IMPORTANT avoid the use of power tools Spinning the nuts too quickly can cause a rapid increase in heat which can cause the nuts to seize as a result of galling or cold welding Note only u...

Страница 10: ...n increased risk that the telephone could be damaged by line born transients Note that user safety from the telephone network is provided by isolation and does not rely on this earth connection Do not...

Страница 11: ...elephone 11 Timer Switch Main Terminal Block The timer is set by the position of switch SW2 Position the switch to the left to set the timer ON and to the right to set it OFF This unit is supplied wit...

Страница 12: ...ure The legend panel is then backlit by the illuminated panel 1 2 3 Press LIFT HANDSET PRESS BUTTON WAIT FOR ANSWER Variable Information Replaceable Legend Panel Fixed Information 6 1 Legend panel dim...

Страница 13: ...g a tab for ease of removal It must not overlap the strip of gasket otherwise the water seal will be compromised 7 Cleaning Recommended cleaning methods are outlined below 7 1 Normal Cleaning For norm...

Страница 14: ...nstallation and commissioning packages and technical support from ad hoc repairs to full maintenance contracts By choosing GAI Tronics as your aftercare provider you are ensured of manufacturer expert...

Страница 15: ...e power Hookswitch Electronic with no external moving parts Time Out 7 minutes 1 Selectable Ringer loudness 80dBA 1m Handset Suitable for inductive coupling to Hearing Aids having a T switch position...

Страница 16: ...rical business equipment Telephony BS6305 1992 with the exception that on hook leakage current is 6mA BS6317 1992 Lightning and transients ITU T recommendation K 21 Enhanced surge protection Recycling...

Страница 17: ...ILC 1117 Titan Illuminated Crossing Telephone 17 10 CE Declaration...

Страница 18: ...18 ILC 1117 Titan Illuminated Crossing Telephone...

Страница 19: ...ILC 1117 Titan Illuminated Crossing Telephone 19...

Страница 20: ...of Hubbell Ltd Brunel Drive Stretton Park Burton on Trent DE13 0BZ England Tel 01283 500500 Fax 01283 500400 www gai tronics co uk The policy of GAI Tronics is one of continuous improvement therefore...