GAI-Tronics DEX-202 Скачать руководство пользователя страница 4

 

Pub.: 42004-679L2D 

M

ODEL 

DEX-10

X AND 

DEX-20

D

RILLER

I

NTERCOM 

S

TATIONS

 

Page 3 of 13 

f:\standard ioms - current release\42004 instr. manuals\42004-679l2d.doc 
10/10

 

Installation 

General Information 

WARNING

  

Always remove power to this station and any associated equipment before 

beginning any installation. 

Install equipment without modification and according to all applicable local and national electrical codes.  
Consult the National Electrical Code (NFPA 70), Canadian Standards Association (CSA 22.1), and local 
codes for specific requirements regarding your installation.  Class 2 circuit wiring must be performed in 
accordance with NEC 725.55. 

CAUTION

 

The factory-sealed section of this station is only to be opened for maintenance or repair by factory 
authorized personnel.  Refer to the “Maintenance” section for more details. 

WARNING

 

After installing station and before applying power, verify that the bolts on the factory-sealed section 
of the station are set at 30 ft-lbs. 

This station has a highly sensitive microphone that allows the user to communicate at a distance from the 
station.  This station also contains a high gain amplifier that enables operation in high noise 
environments. 

To prevent feedback problems in the system, the ambient noise levels, volume settings, and station 
placement must be taken into consideration.  In most cases, stations can be mounted perpendicular to the 
same surface and be placed 150 feet apart.  This minimum spacing requirement between stations can be 
reduced under the following conditions: 

 

the stations are installed in a high noise environment; 

 

they are configured for simplex mode (depressing 

T

 button); 

 

they contain speaker L-pads; 

 

they are placed in separate rooms. 

Содержание DEX-202

Страница 1: ...rview 1 System Requirements and Limitations 1 Features and Functions 2 Available Models 2 Description of Major Components 2 Installation 3 General Information 3 Mounting 5 Conduit Installation 5 Field...

Страница 2: ...ng platforms especially in hazardous areas It provides all call group call and point to point communications and is available in digital and analog versions The enclosure is rated NEMA 4X and is facto...

Страница 3: ...keypad 24 V dc UL DEX 202 Digital Intercom Station with keypad 120 V ac UL Description of Major Components The Driller s Intercom stations consist of a factory sealed enclosure top and a termination...

Страница 4: ...authorized personnel Refer to the Maintenance section for more details WARNING After installing station and before applying power verify that the bolts on the factory sealed section of the station are...

Страница 5: ...Pub 42004 679L2D MODEL DEX 10X AND DEX 20X DRILLER S INTERCOM STATIONS Page 4 of 13 f standard ioms current release 42004 instr manuals 42004 679l2d doc 10 10 Figure 2 Driller s Intercom Outline...

Страница 6: ...y fasten the factory sealed and termination enclosures to the mounting location using steel mounting bolts and washers or washer head bolts hardware not included Conduit Installation Install the condu...

Страница 7: ...o be completed in the termination enclosure bottom enclosure only NOTE Consult the National Electrical Code NFPA 70 Canadian Standards Association CSA 22 1 and local codes for the specific requirement...

Страница 8: ...r must be supplied by an isolated 24 V dc power source Additional power feeds may be required to increase the system distance and or the number of stations NOTE Isolated dc power sources must be used...

Страница 9: ...ions require termination of a 2 conductor twisted pair cable on system terminals A and B only Analog stations require termination of a 4 conductor twisted pair cable A B twist C D twist on system term...

Страница 10: ...rd ioms current release 42004 instr manuals 42004 679l2d doc 10 10 System Interconnection Refer to Figure 6 for a typical system wiring diagram Consult the Central Switch manual for further details on...

Страница 11: ...o from the slave station is broadcast over this station s speaker when the T button or footswitch is released Point to Point Communication Refer to the Direct Dialing section of the Central Switch man...

Страница 12: ...nication Communication with this station can be enabled when another station dials the extension of this station 1 The LED on the front panel illuminates to indicate a call is in progress NOTE The bea...

Страница 13: ...ion Refer to the Volume Configuration section of the Central Manual for details High speaker volume Decrease the actual and or maximum volume settings in the configuration Refer to the Volume Configur...

Страница 14: ...e amplifier Frequency response 200 4 000 Hz 3 dB ref 1 kHz Speaker amplifier Output Class AB 18 watts min into 8 ohms with nominal supply voltage Frequency response 200 10 000 Hz 3 dB ref 1 kHz Distor...