Warranty

Equipment.

  GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any

GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall
comply with the then-current product specifications and product literature, and if applicable, shall be fit
for the purpose specified in the agreed-upon quotation or proposal document.  If (a) Seller’s goods prove
to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose
specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above,
Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time
they will be repaired or replaced, at Seller’s option, without charge to Buyer.  Repair or replacement shall
be Buyer’s sole and exclusive remedy.  The warranty period on any repaired or replacement equipment
shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original
equipment was shipped.  In no event shall GAI-Tronics warranty obligations with respect to equipment
exceed 100% of the total cost of the equipment supplied hereunder.  Buyer may also be entitled to the
manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder.  The applicability
of any such third-party warranty will be determined by GAI-Tronics.

Services.

  Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,

shall be performed in accordance with the standard of care with which such services are normally
provided in the industry.  If the services fail to meet the applicable industry standard, GAI-Tronics will
re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided
any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work
site.  Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAI-
Tronics warranty obligations with respect to services exceed 100% of the total cost of the services
provided hereunder.

Warranty Periods.

  Every claim by Buyer alleging a defect in the goods and/or services provided

hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty
periods as set forth above.  Provided, however, that if the defect complained of is latent and not
discoverable within the above warranty periods, every claim arising on account of such latent defect shall
be deemed waived unless it is made in writing within a reasonable time after such latent defect is or
should have been discovered by Buyer.

Limitations / Exclusions.

  The warranties herein shall not apply to, and GAI-Tronics shall not be

responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent
caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the
equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the
equipment.  THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND
EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY
OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Return Policy

If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#).  Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number.  If the equipment is under warranty, repairs or a replacement will be made in
accordance with the warranty policy set forth above.  Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.

Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the
Regional Service Center closest to you.

Содержание 4512-001

Страница 1: ...ons 1 Description 2 Connectors 3 Power Connector 3 Speaker Connector 4 Microphone Connector 4 Antenna Connector 4 Channel Selector Switch 4 Radio Transceiver Module 5 Interface PCBA 5 Pot R7 5 Wide Ra...

Страница 2: ...Battery Connections 13 Microphone Connection 13 Speaker Connection 13 Programming 14 Power Supply Adjustment 14 Speaker Output Adjustment 14 Operation 15 Initiating Calls 15 Receiving Calls 15 Contro...

Страница 3: ...arty General Information Scope of Manual This manual provides descriptive data and service information for the following GAI Tronics 6 Channel Radios Model 4512 001 270 V dc Frequencies programmed by...

Страница 4: ...4 14 H 3 00 D inches The housing is also a mounting bracket and includes an integral handle The mounting bolts double as support feet when the unit is placed horizontally on a flat surface such as on...

Страница 5: ...he location of the connectors and channel selector switch PowerConnector Refer to Figure 3 for the locations of the connectors The pinout for the power connector is as follows Table 1 Model 4512 001 C...

Страница 6: ...ur to the speaker and or radio Jumper P6 must be in position 2 3 to activate the carrier detect output Refer to Table 6 on page 5 and Figure 7 on page 12 MicrophoneConnector The microphone pinout is a...

Страница 7: ...equencies Do not attempt to program the radio for these frequencies Table 5 UHF 450 470 MHz Receive MHz Transmit MHz 460 80000 460 78750 461 23750 460 79375 461 24375 460 80625 461 25625 460 81250 461...

Страница 8: ...nge of input voltages and in addition to the internal protection it is further protected from transients on the external power source by the optional Surge Filter PCBA The power supply provides regula...

Страница 9: ...Channel Radios are designed to operate with a rechargeable battery When installed the standby emergency battery supplies power for up to 15 minutes of normal run time with RF set to low power setting...

Страница 10: ...computing devices must contain warnings about possible interference with local residential radio and TV reception This warning reads as follows NOTE This equipment has been tested and found to comply...

Страница 11: ...ircuit module 4 When servicing a circuit module avoid carpeted areas dry environments and certain types of clothing silk nylon etc because they contribute to static build up Similarly disconnect the t...

Страница 12: ...al sheathed or metal clad or are permanently separated from the conductors of the other circuitry by a continuous and firmly fixed nonconductor such as porcelain tubes or flexible tubing in addition t...

Страница 13: ...ng the 25 foot coax antenna cable Refer to Figure 6 and Figure 7 for the Models 4512 001 and 4514 001 respectively Select an area for antenna mounting that gives the antenna an unobstructed view of th...

Страница 14: ...004 387G Model 4512 001 4512 001FR 4514 001 and 4514 001FR 6 Channel Radios Page 12 of 19 f standard ioms current release 42004 instr manuals 42004 387g doc 02 15 Figure 7 Model 4514 001 Connection Di...

Страница 15: ...follows Refer to Figure 4 on page 7 1 Loosen the mounting screw on the right of the 63069 013 Battery Bracket and lift it out of the keyhole slot Slide the battery into place Replace the bracket and...

Страница 16: ...tery The charging current can be adjusted using Pot 2 on the Power Supply PCBA Refer to Figure 4 on page 7 for location of Pot 2 If field adjustment becomes necessary the procedure is as follows 1 Dis...

Страница 17: ...allow time for the radio channel to be established 2 Speak directly into the microphone held approximately 1 2 inch from the mouth The microphone button must be held down while talking to the radio us...

Страница 18: ...ive or malfunctioning equipment should be returned to the factory for repair Please call 1 800 492 1212 or 610 777 1374 to obtain a Return Authorization number published repair prices and shipping ins...

Страница 19: ...re 1 0A Slo Blo 5 20mm 250V UL CSA Interface PCBA fuse F2 is 0 1A Slo Blo 5 20mm 250V UL CSA Battery Replacement The optional standby emergency battery is designed to have a shelf life of approximatel...

Страница 20: ...r 8 watts maximum into 8 ohms UHF Radio Transceiver General FCC ID AIERT17 445 Frequency range 450 470 MHz Frequency stability 1 5 ppm Tone code signaling CTCSS Quiet Call and DCS Transmitter RF power...

Страница 21: ...lead acid 40201 004 Field Replacement Items Description Part No Fuse F1 Power Supply PCBA 1 25A Slo Blo 2AG 250V axial leaded UL CSA 4612 23015 25 Fuse F2 Power Supply PCBA 1 6A Slo Blo 5 20mm 250V U...

Страница 22: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: