4.5  Mounting Methods 

4.5.1 

Wall Mounting 

To ensure weatherproof integrity when wall mounted, external cables 
should enter the enclosure from the bottom via the two 20mm gland 
entries provided. 

IMPORTANT WARNING: 

DO NOT DRILL ANY EXTRA HOLES AS THIS WILL INVALIDATE 

YOUR WARRANTY. 

1.  Remove rubber feet from the Rear Casing if fitted. Ensuring that the 

cable entries are at the bottom offer the Rear Casing up to the 
vertical surface and mark through the fixing holes.  

Do not use the Rear Casing

 

as a template to drill the holes.  

Work only from the marked positions

2.  Drill the holes in the vertical surface to suit the best method of fixing.  

3.  Ensure the Rear Casing is securely attached to the vertical surface 

using the four 7mm diameter screw holes provided. No sealing 
washers are necessary. 

IMPORTANT: 

Do not use countersunk headed fixing screws. Only 

use round head, socket cap head or pan head screws. Take care not 
to over tighten the screws as doing so may damage the case and 
will invalidate your warranty. 

4.  Pass the cable through the gland and tighten, following the gland 

manufacturer’s instructions. 

5.  Continue the installation procedure with the connection of individual 

wires from the cable as described under sections 4.6 onwards. 

4.5.2 

Pole-side Mounting   

Kit No 100-02-0208-001  

 

 

Содержание 1114

Страница 1: ...ation and User Guide Commander VoIP Telephone 1114 model with Headset socket IMPORTANT THIS PRODUCT MUST BE CONFIGURED PRIOR TO INSTALLATION PLEASE READ THIS GUIDE FIRST GAI TRONICS A Division of Hubb...

Страница 2: ...ase 18 5 Operation 20 5 1 Making and Receiving Calls 20 5 2 Last Number Redial 21 5 3 Recall Function 21 5 4 Secrecy or Mute Function 21 5 5 Headset Operation 22 6 Maintenance 23 6 1 Procedures 23 6 2...

Страница 3: ...unit before opening the case This product must be configured prior to installation See section 4 2 1 for details Some versions of this product are supplied with long handset or headset cables which co...

Страница 4: ...Commander 1114 VoIP 3 2 Product Description Commander 1114 VoIP Telephone at a glance Rear case Front case Ringer Handset Keypad Main PCB User terminals Gland entries...

Страница 5: ...or armoured stainless steel cord Hearing aid compatible inductive coupling as standard Headset option available Integral 90dBA ringer with volume adjustment Programmable volt free contact output Avai...

Страница 6: ...ing physically fixing the unit in pace Connection attach cables Testing ensure it functions as expected Put into service finalise the installation 4 2 Pre installation Please ensure that each unit is...

Страница 7: ...IP address user name or password that the new details are recorded and securely kept If these details are lost it will not be possible to access the unit s configuration web pages If this occurs the...

Страница 8: ...nnection schemes in section 4 6 5 to ensure that the required connections can be made using the available glands For example Power over Ethernet PoE is the recommended method of providing power to avo...

Страница 9: ...01 The holes are arranged in a rectangle as follows Horizontal separation between centres 145 0mm Vertical separation between centres 270 0mm The lower pair are about 10mm up from the bottom edge of t...

Страница 10: ...e Front Casing from the Rear Casing The screws are captive in the Front Casing 3 Noting the positions disconnect the keypad cable at the keypad See diagram in section 4 8 4 Disconnect the ringer cable...

Страница 11: ...nly from the marked positions 2 Drill the holes in the vertical surface to suit the best method of fixing 3 Ensure the Rear Casing is securely attached to the vertical surface using the four 7mm diame...

Страница 12: ...ighten the straps firmly and trim off any excess band material For security the driving head of the band may also be sawn off 4 5 3 Desk Mounting Rake IMPORTANT WARNING Risk of impact or falling This...

Страница 13: ...Commander 1114 VoIP 12 3 Continue the installation procedure with the connection of individual wires from the cable as described in sections 4 6 onwards Providing the rake...

Страница 14: ...relay if required Details of each connection are given below There are a number of possible cabling schemes illustrated at the end of the section 4 6 1 Ethernet connections The Ethernet port is provid...

Страница 15: ...n earth point which needs to be connected to the equipotential bonding system for the whole area in which the equipment is being used using one of the following 1 At least two separate conductors each...

Страница 16: ...etc Refer to the configuration guide for full details available from www gai tronics org support voip support CONTACT RATING Maximum voltage 253Vrms nominal 230V Maximum current 5A Note no fusing or...

Страница 17: ...those with a maximum flash intensity of 5 joules Where beacons with greater than 5 joule flash intensity are required the beacons should be purchased direct from GAI Tronics who will carry out a free...

Страница 18: ...Commander 1114 VoIP 17...

Страница 19: ...the configuration guide covers all models of GAI Tronics VoIP telephone Specifically the Commander 1114 does not include the following features External inputs LEDs Serial port Only a single relay OUT...

Страница 20: ...e will not be trapped when the Front Casing is tightened down Take care that all folds are made the ribbon cable can lay flat and that the insulation can not become damaged Check also that the environ...

Страница 21: ...gits or press required memory button or Last Number Redial where fitted and wait for connection Memory buttons are associated with memory lists on the Dialling and Memories Memory Lists web page ie M1...

Страница 22: ...y or neck 5 2 Last Number Redial 15 and 18 button versions only Press LR to redial the last dialled number 5 3 Recall Function 15 and 18 button versions only The R button can be used to pulse a relay...

Страница 23: ...switch to the I position 3 To terminate the call turn the switch to the 0 position 4 To remove the headset pull the body of the connector to release the latching mechanism Do not attempt to disconnect...

Страница 24: ...leaning Security of the installation on wall pole or post Security and integrity of cable entries Security of the three body screws Cleanliness integrity and condition of the handset Wipe clean as nec...

Страница 25: ...nts Overstressing of screws Insecure fixing Incorrect installation of glands Section 4 4 Incorrect wiring or cable connections Section 4 6 Improper reassembly following connection Additional holes dri...

Страница 26: ...to ETS 300 381 Network 10 100 BaseT Ethernet RJ45 Cat5 or Cat5e STP Static IP provisioning or DHCP Call control signalling SIP RFC3261 compliant Loose routing External inputs None External output Outp...

Страница 27: ...set cord is approximately 820mm long and can extend to approximately 2m dependant on safe operating conditions A separate headset extension lead is available as an optional extra part No 610 35 2036 0...

Страница 28: ...nd Regulations Commander 1114 is fully compliant with the following 7 6 1 EMC Testing to EN55022 2006 Class B Information technology equipment Radio disturbance characteristics EN55024 1998 Informatio...

Страница 29: ...o ISO9001 2000 Certificate No 861888 7 7 Recycling Information The symbol shown here and on the product means that the product is classed as Electrical or Electronic Equipment and should not be dispos...

Страница 30: ...s The firmware in GAI Tronics VoIP products contains modules subject to licensing and copyright as follows Module License u boot GPL V2 Linux kernel GPL V2 Busybox GPL V2 Opal PWLib Mozilla Public Lic...

Страница 31: ...Commander 1114 VoIP 30...

Страница 32: ...ou have any difficulties please call The policy of GAI Tronics is one of continuous improvement therefore the Company reserves the right to change specifications without notice The contents of this pu...