Pub. 42004-708L2B 

Model 10962-001 and 10962-002 AMI Redundant Controller Modules 

Page:  14 of 17 

f:\standard ioms - current release\42004 instr. manuals\42004-708l2b.doc 
06/10 

Maintenance 

ARC Diagnostics 

There are two board level diagnostic tests available that are enabled by setting the ADDR switch.  The 
top cover must be removed from the ARC module to allow the test LEDs to be observed. 

VOX Input Test 

When ADDR switch is set to “A,” followed by a board reset, the LCD will show 

DIAG:

 

VOX

 

I

NPUT

.  

This indicates that the ARC board is in diagnostic mode for the VOX1 and VOX2 inputs. 

When audio is detected on VOX1, LED 3 on the PCBA illuminates.  LED 3 turns off when audio is no 
longer detected at the VOX1 input.  Likewise, when audio is detected on VOX2 input, LED 4 
illuminates.  LED 4 turns off when audio is no longer detected at the VOX2 input. 

Input/Output (Switch B) 

When ADDR switch is set to “B,” followed by a board reset, the LCD will show 

DIAG:

 

I/O

.  This 

indicates that the ARC board is in the diagnostic mode for testing the inputs and outputs. 

When Input 1 is activated, Output 1 will be activated.  When Input 2 is activated, Output 2 will be 
activated, etc.  This sequence is true for Input 1 through Input 8. 

Содержание 10962-001

Страница 1: ...senger Interface AMI units The AMI acts as the alarm tone speech generator to produce emergency tones and or pre recorded speech messages Refer to Pub 42004 399 for more information on the Model 10959...

Страница 2: ...CD module mounted to the front of the base Model 10962 002 Dual Redundant Controller has two 69842 001 AMI Redundancy Controller PCBAs mounted to the base and has two LCD modules mounted to the front...

Страница 3: ...r Modules Page 3 of 17 f standard ioms current release 42004 instr manuals 42004 708l2b doc 06 10 Block Diagrams Figure 3 shows the equipment block diagram when the ARC module and AMIs are installed i...

Страница 4: ...quipment block diagram when the ARC modules and AMIs are installed in two different locations NOTE When using a CAT 5 cable to directly connect the two ARC modules as illustrated the maximum distance...

Страница 5: ...rovided 2 Mount the AMI Redundant Controller into the rack using four 10 32 inch screws with plastic shoulder washers Wiring Terminations The Model 10962 001 AMI Redundant Controller provides three te...

Страница 6: ...Redundant Controller Modules Page 6 of 17 f standard ioms current release 42004 instr manuals 42004 708l2b doc 06 10 Refer to Figure 6 for a typical connection diagram between the ARC and the AMI Figu...

Страница 7: ...08L2B Model 10962 001 and 10962 002 AMI Redundant Controller Modules Page 7 of 17 f standard ioms current release 42004 instr manuals 42004 708l2b doc 06 10 Figure 7 ARC and the 200 Series AMI Connect...

Страница 8: ...Figure 6 NOTE When using the RS 485 data connection the RS 232 cannot be used and vise versa VOX 1 The VOX 1 terminals are for sampling the audio output of the AMI When the AMI is playing a message th...

Страница 9: ...o on the AMI output during the playing of an alarm message or page 2 Ethernet Fault This output becomes active when the Ethernet Network connection is broken between the ARC modules and they can no lo...

Страница 10: ...rogrammed as either a Silence input or Reset input Silence input If the AMI is playing a message and has one or more messages in queue and a Silence input contact is detected the currently playing mes...

Страница 11: ...erly Connect the GND connection on the Logic Inputs terminal block on the ARC to the GND connection on the Digital Inputs terminal block on the AMI ARC Pin No Function AMI Pin No Notes 1 Spare 1 2 Dat...

Страница 12: ...aying a message or page AMI MUTED The AMI s audio output is muted but the AMI is playing a message or a telephone page AMI FAILED The AMI has denied a request from the ARC or the AMI has returned an u...

Страница 13: ...the output is muted by the ARC mute input This symbol indicates a working Ethernet connection between the two ARC modules Absence of the icon indicates an Ethernet problem This symbol indicates that m...

Страница 14: ...cates that the ARC board is in diagnostic mode for the VOX1 and VOX2 inputs When audio is detected on VOX1 LED 3 on the PCBA illuminates LED 3 turns off when audio is no longer detected at the VOX1 in...

Страница 15: ...he unit depends on the setting of the ADDR switch When the ADDR switch is set to 0 the ARC is the Primary controller and the IP address is 192 168 1 151 When the ADDR switch is set to 1 the ARC is the...

Страница 16: ...n and switches control to the back up AMI The range is 5 10 seconds in 1 second increments The default value is 5 seconds This parameter may need to be altered if there are pause silence times in the...

Страница 17: ...ge in the event that data communication is lost while an alarm is active All other settings regarding the AMI configuration can be project specific Specifications Power Supply Requirements Connection...

Страница 18: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: