Installation 

Figure 2 shows the wiring details for the Centra-
Page Electrical Safety Barrier.  The Model 10439-
102 Electrical Safety Barrier should be installed 
before any of the associated Station Line Cards are 
plugged into the Centra-Page Card Rack. 

1.

 

Remove the cover from the front of the Model 
10439-102 Electrical Safety Barrier. 

2.

 

The barrier enclosure is not provided with 
conduit openings because the location of these 
openings will vary between installations.  
Determine the location of the conduit openings.  
Drill or punch the holes in the enclosure. 

N

OTE

:

  Bottom or side entry for the openings 

is advised because condensation and liquids 
can most easily enter the enclosure from the 
top. 

3.

 

Figure 1 shows the mounting details for the 
Model 10439-102 Electrical Safety Barrier.  
Mount the barrier as shown in the figure. 

4.

 

Wire the barrier as shown in Figure 2. 

5.

 

Replace the front cover of the barrier. 

 

Figure 2.  Centra-Page Wiring Details 

 

Figure 1.  Mounting Details 