![GAI-Tronics 10439-102 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/gai-tronics/10439-102/10439-102_manual_3183455002.webp)
Pub. 42004-358A
Model 10439-102 Electrical Safety Barrier for Centra-Page Systems
Page: 2 of 3
\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-358a.doc
06/04
Installation
Figure 2 shows the wiring details for the Centra-
Page Electrical Safety Barrier. The Model 10439-
102 Electrical Safety Barrier should be installed
before any of the associated Station Line Cards are
plugged into the Centra-Page Card Rack.
1.
Remove the cover from the front of the Model
10439-102 Electrical Safety Barrier.
2.
The barrier enclosure is not provided with
conduit openings because the location of these
openings will vary between installations.
Determine the location of the conduit openings.
Drill or punch the holes in the enclosure.
N
OTE
:
Bottom or side entry for the openings
is advised because condensation and liquids
can most easily enter the enclosure from the
top.
3.
Figure 1 shows the mounting details for the
Model 10439-102 Electrical Safety Barrier.
Mount the barrier as shown in the figure.
4.
Wire the barrier as shown in Figure 2.
5.
Replace the front cover of the barrier.
Figure 2. Centra-Page Wiring Details